Table B-10. Set Config Zoning Parameters

B – Command Line Interface Set Config Command

Q

zoning

Initiates an editing session in which to change switch zoning attributes. The system displays each parameter one line at a time and prompts you for a value. For each parameter, enter a new value or press the Enter key to accept the current value shown in brackets.

Table B-10. Set Config Zoning Parameters

Parameter

Description

 

 

AutoSave

Enables (True) or disables (False) the

 

saving of changes to active zone set in

 

the switch’s permanent memory.

 

Changes are always saved in the

 

switch’s temporary memory.

Default

Enables (All) or disables (None)

 

communication among the switch’s

 

ports/devices and the fabric in the

 

absence of an active zone set.

 

 

Examples The following is an example of the Set Config Port command:

SANbox2 #> admin start

SANbox2 (admin) #> config edit

SANbox2 (admin-config) #> set config port 1

A list of attributes with formatting and current values will follow.

Enter a new value or simply press the ENTER key to accept the current value.

If you wish to terminate

this process before reaching the end of the list

press 'q' or 'Q' and the

ENTER key to do so.

 

 

Configuring Port Number:

1

 

 

------------------------

 

 

 

AdminState

(1=Online,

2=Offline, 3=Diagnostics, 4=Down)

[Online]

LinkSpeed

(1=1Gb/s, 2=2Gb/s, 3=Auto)

[Auto

]

PortType

(TL / GL /

G / F / FL / Donor)

[GL

]

ISLSecurity

(Any / Ours / None)

[Any

]

SymPortName

(string, max=32 chars)

[Port1 ]

ALFairness

(True / False)

[False ]

DeviceScanEnable (True /

False)

[True

]

ForceOfflineRSCN (True /

False)

[False

]

ARB_FF

(True / False)

[False

]

InteropCredit

(decimal value, 0-255)

[0

]

ExtCredit

(dec value, increments of 11, non-loop only)

[0

]

B-30