4 – Managing Switches Configuring Alarms

Q

6.Enter a value for the rising threshold. A rising threshold alarm is generated when the event count exceeds the rising threshold. The switch will not generate another rising threshold alarm for that event until the count descends below the falling threshold and rises again above the rising threshold. Consider the example in Figure 4-7.

Note: The switch will down a port if a rising threshold alarm is not cleared after three consecutive sample intervals.

Generate rising

 

Generate rising

threshold alarm;

 

threshold alarm;

eligibility ends

 

eligibility ends

 

 

Rising

Event

 

Threshold

Count

 

 

 

 

Falling

 

Generate falling

Threshold

 

 

 

threshold alarm;

 

 

eligibility is reset

 

Sample Interval

Figure 4-7. Alarm Threshold Example

7.Enter a sample interval in seconds. The sample interval defines the period of time in which to count events.

8.Check the Enable box to make the alarm eligible for use. Repeat steps 3 through 8 for each alarm you want to configure or enable. You must also check the Enable All Alarm Thresholds box, which is the master control for all alarm configurations.

9.Choose the OK button to save all changes.