Q

A – Command Line Interface Set Config Command

Table A-11. Set Config Threshold Parameters (Continued)

Parameter

Description

 

 

Rising Trigger

The event count above which a rising threshold

 

alarm is logged. The switch will not generate

 

another rising threshold alarm for that event until

 

the count descends below the falling threshold

 

and again exceeds the rising threshold.

Falling Trigger

The event count below which a falling threshold

 

alarm is logged. The switch will not generate

 

another falling threshold alarm for that event until

 

the count exceeds the rising threshold and

 

descends again below the falling threshold.

Sample Window

The period of time in seconds in which to count

 

events.

 

 

zoning

Initiates an editing session in which to change switch zoning attributes. The system displays each parameter one line at a time and prompts you for a value. For each parameter, enter a new value or press the Enter key to accept the current value shown in brackets.

Table A-12. Set Config Zoning Parameters

Parameter

Description

 

 

FC-SW-2 AutoSave

Available only when the FC-SW-2

 

Compliant parameter is True, this

 

parameter enables (True) or disables

 

(False) the saving of changes to active

 

zone set in the switch’s permanent

 

memory. Refer to ”FC-SW-2 Compliant” on

 

page A-36. The default is True.

Default

Enables (All) or disables (None)

 

communication among the switch’s ports/

 

devices and the fabric in the absence of an

 

active zone set. The default is All.

 

 

59048-02 A

A-37

Page 151
Image 151
Q-Logic 59048-02 A manual Table A-12. Set Config Zoning Parameters, Memory. Refer to FC-SW-2 Compliant on