Q-Logic 59048-02 A manual Table A-11. Set Config Threshold Parameters

Models: 59048-02 A

1 226
Download 226 pages 50.27 Kb
Page 150
Image 150

A – Command Line Interface Set Config Command

Q

Table A-10. Set Config Switch Parameters (Continued)

Parameter

Description

 

 

FC-SW-2 Compliant

Propagates just the active zone set

 

throughout the fabric (True, compliant) or

 

the entire zoning database (False, non-

 

compliant). The default is True.

LegacyAddressFormat

Available only when the FC-SW-2

 

Compliant parameter is False, this

 

parameter enables (True) or disables

 

(False) the use of legacy address

 

formatting for interoperating with non-FC-

 

SW-2 switches. Refer to ”FC-SW-2

 

Compliant” on page A-36. The default is

 

False.

 

 

threshold

Initiates a configuration session by which to generate and log alarms for selected events. The system displays each event, its thresholds, and sampling interval one line at a time and prompts you for a value. For each parameter, enter a new value or press the Enter key to accept the current value shown in brackets. These parameters must be saved in a configuration and activated before they will take effect. Refer to the ”Config Command” on page A-7for information about saving and activating a configuration. Table A-11describes the Set Config Threshold parameters. The switch will down a port if an alarm condition is not cleared within three consecutive sampling intervals (by default 30 seconds). Reset the port to bring it back online. An alarm is cleared when the threshold monitoring detects that the error rate has fallen below the falling threshold.

Table A-11. Set Config Threshold Parameters

Parameter

 

Description

 

 

Threshold Monitoring Enabled

Master enable/disable parameter for all events.

 

Enables (True) or disables (False) the generation

 

of all enabled event alarms. The default is False.

CRCErrorsMonitoringEnabled

The event type enable/disable parameter.

DecodeErrorsMonitoringEnabled

Enables (True) or disables (False) the generation

ISLMonitoringEnabled

of alarms for each of the following events:

LoginMonitoringEnabled

„

CRC errors

LogoutMonitoringEnabled

„

Decode errors

LOSMonitoringEnabled

„

ISL connection count

 

„

Device login errors

 

„

Device logout errors

 

„ Loss-of-signal errors

 

 

 

A-36

59048-02 A

Page 150
Image 150
Q-Logic 59048-02 A manual Table A-11. Set Config Threshold Parameters