OPERATION

LAMP ADJUST

Whenever you install a new lamp in the projector you need to access the Lamp Adjust submenu and record the lamp serial number in the projector's memory. You can also set different Lamp submenu options such as intensity (output) or power required. These setups can be changed at any time.

NOTE: See 2.2, Installing The Lens for complete instructions on installing a new lamp in the projec- tor.

Lamp Adjust

Xenon Lamp Hours

015

 

 

 

 

New Xenon Lamp Serial No.

2LJa869

 

Lamp Message

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1000

 

 

 

 

Xenon Lamp Limit

 

 

 

 

 

 

 

 

 

 

 

 

Xenon Lamp Mode

 

 

 

 

Max Output

 

Constant Power

1000

 

 

 

 

 

 

 

 

Constant Intensity

4114

 

 

 

 

 

 

 

 

Xenon Lamp History

 

 

 

 

 

 

 

Replace Xenon Lamp

 

 

 

 

 

 

 

Lamp Adjust submenu

From the Advanced menu, select the "Lamp Adjust" option for access to the Lamp Adjust sub- menu, where all lamp functions and data appear. Read-only information includes the number of hours logged on the lamp so far and the serial number

recorded for the installed lamp.

XENON LAMP HOURS shows the number of hours logged on the current lamp. Whenever you record a new lamp serial number, this value automatically resets to "0", where it begins to log time for the new lamp. Note: Read-only. This information also appears in the Information menu.

New XENON Lamp Serial No. is the serial number recorded for the current lamp. When you install a new lamp and enter its serial number, the number will appear here in the Xenon Adjust menu. Note: Read-only.

Enter a checkmark for LAMP MESSAGE if you want to enable a warning message upon power- up that the lamp has reached the specified lamp limit and should be replaced. Delete the check- mark if you do not want to see this warning-instead, when your lamp expires, only the status information on the back of the projector will provide the warning to replace the lamp.

NOTES: 1) It is recommended that the Lamp Message checkbox remain enabled. 2) When a lamp warning message appears, press to temporarily cancel the message. The message will continue to appear upon power-up until you install a new lamp.

Set XENON LAMP LIMIT to the number of hours you expect to log on the current lamp before replacing it. The recommended limit is 1000 hours. At lower power settings, 2000 hours is pos- sible.

NOTE: 1) If you change modes over the life of a lamp, the lamp limit you originally expected may no longer be possible. 2) Turning the lamp on and off reduces lamp life significantly, as do other factors.

Set which XENON LAMP MODE you want to use in order to control the light output. Although there are exceptions, in most lamps, the high- er the light output or power setting, the shorter the life span of the lamp.

Max Output

Constant Intensity Constant Power

3-35