nDIP-Switch Functions

nDIP-Switch Functions

Table 3-2. DIP-switch Functions

DIP SW

ON

OFF

 

 

 

 

 

 

 

 

SW-1

Ignores data reception errors

Prints “?” for data reception errors

 

SW-2

Data buffer 45 bytes

Data buffer 4 Kbytes

 

 

 

 

 

 

 

 

SW-3

XON/XOFF control

DSR/DTR

control

 

 

 

 

 

 

 

SW-4

With parity

without

parity

 

 

 

 

 

 

SW-5

Even parity

Odd parity

 

SW-6

Change baud rate (Refer to Table 3-3)

 

 

 

 

 

 

 

 

 

SW-7

 

 

 

 

 

 

 

 

 

 

SW-8

Change print density (Refer to Table 34)

 

 

 

 

 

 

 

 

 

SW-9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW-10

Thermal label paper

Thermal paper

 

 

 

 

 

 

 

Table 3-3. Baud Rate Selection

Baud Rate

SW 1-6

SW 1-7

 

 

 

1200 bps

ON

ON

4800

OFF

O N

 

 

 

9600

ON

OFF

 

 

 

19200

OFF

OFF

 

 

 

Table 3-4. Print Density Selection

Print Density

SW 1-8

SW 1-9

Level

 

 

 

 

 

 

LIGHT

ON

ON

1

 

I

OFF

OFF

2

 

I

 

 

 

 

ON

OFF

3

 

I

 

 

 

 

 

 

 

4

 

DARK

OFF

ON

 

 

 

 

 

 

13

Page 19
Image 19