Seiko Group TM-L60 manual ESC t n, ESC u n

Models: TM-L60

1 79
Download 79 pages 57.83 Kb
Page 46
Image 46

[Description]

The pulse defined

by nl and n2 is output on connector pin m.

 

m is specified as

follows:

m

Connector pin

0Drawer kick-out connector pin 2

1 Drawer kick-out connector pin 5

 

l ON time is nl X 2 ms and OFF time is n2 X 2 ms.

 

The circuit on the user side should be designed so that the

 

drawer drive duty is as shown below.

 

 

ON time

 

 

 

(ON time + OFF time)

 

It is recommended that n2 be four times as much as nl or more.

[Notes]

l If m is out of range, the printer reads n1 and n2 but does not

 

output a pulse.

[Default]

Neither m, n1, nor n2 is defined.

ESC t n

[Name]

Select character code table

[Format]

<1B>H<74>H<n>

[Range]

[Description]

Selects page n from the character code table.

[Default]

n = 0

[Reference]

APPENDIX D Character Code Tables

ESC u n

[Name]

Transmit printer status

[Format]

<1B>H<75>H<n>

[Range]

n = 0

[Description]

Transmit the current status of connector pin.

 

l n is specified as follows:

n

Connector pin

 

 

0

Drawer kick-out connector pin 3

 

 

 

 

40