W i t h c o u n t - d o w n

Counts down n1 + n2 x 256 > n3 + n4 x 256, n5 ¹ 0, and n6 ¹

0.

n1 + n2 x 256 means the maximum counter value and n3 + n4 x 256 the minimum counter value.

T o s t o p c o u n t i n g

 

Stops counting if n1 + n2 x 256 = n3 + n4 x 256, n5 = 0, or n6 =

 

 

0 .

 

n5 indicates the stepping amount when counting up or down.

 

n6 indicates repetition number with the counter value being

 

 

fixed.

[Notes]

When this command is issued, the inner counter that indicates

 

 

the repetition number specified by n6 will be cleared.

 

W i t h c o u n t - u p

 

If counting up reaches a value exceeding the maximum, it is

 

 

resumed with the minimum value.

 

With count-down

 

If counting down reaches a value less than the minimum, it is

 

 

resumed with the maximum.

[Default]

n1 + n2 x 256 = 1, n3 + n4 x 256 = 65535, n5 = 1, n6 = 1

[Reference]

GS CO, GS C2, GS c, GS C;

GS C2 n1 n2

[Name]

[Format]

[Range]

[Description]

[Notes]

Set counter <1D>H<43>H<32>H<n1><n2>

0

n1 2 5 5

0

n2 2 5 5

Sets the value of the serial number counter.

n1 + n2 x 256 is the counter value.

When this command is issued, the inner counter that counts repetition number with the counter value fixed will be cleared.

W i t h c o u n t i n g u p

If the counter value set by this command goes out of the counter operation range set by GS Cl or GS C;, it will be forced to convert to the minimum value by GS c.

W i t h c o u n t i n g d o w n

If the counter value set by this command goes out of the counter operation range set by GS Cl or GS C;, it will be forced to convert to the maximum value by GS c.

48

Page 54
Image 54
Seiko Group TM-L60 manual GS C2 n1 n2, T h c o u n t d o w n