GS ^ n1 n2 n3

GS ^ n1 n2 n3

[Name]

Execute macro

[Format]

< 1 D > H < 5 E > H < n 1 > < n 2 > < n 3 >

[Range]

0 n1 255

 

0 n2 255

 

0 n3 l

[Description]

Executes a macro.

 

n1: Specifies the number of times to execute the macro.

 

n2: Specifies the waiting time for executing the macro.

 

n2 x 100 msec waiting time is required for one execution.

 

n3: Specifies the macro executing mode.

 

n3 = 0 Continuous macro execution.

 

Executes n1 times continuously at the interval speci-

 

fied by n2.

 

n3 = 1 Executes the macro with the paper feed switch.

 

After waiting the period specified by n2, the error LED

 

blinks and the printer waits for the paper feed switch to

 

be pressed. After the paper feed switch is pressed,

 

the printer executes the macro once.

 

The printer repeats this operation n1 times.

[Notes]

If this command is received while defining the macro, the macro

 

definition is aborted, and the definition is cleared.

 

If the macro is not defined or if n1 is 0, nothing is executed.

 

Paper cannot be fed with the paper feed switch while executing

 

the macro when n3 is 1.