Sierra S5832SG installation instructions Block 3 - Armed System Programming cont

Models: S5832SG

1 44
Download 44 pages 10.6 Kb
Page 21
Image 21
Block 3 - Armed System Programming (cont.)

Block 3 - Armed System Programming (cont.)

Quick Bypass Enable

Comments

Cmd Loc

006

 

If enabled, quick bypass allows any user to bypass zones

Default

1

 

without entering a user code. To bypass a zone, press the

Range

1 - 2

 

[Bypass] key followed by the 2-digit code for the zone to be

 

 

 

bypassed.

 

 

 

Options:

1No

2 Yes

Home Arm Exit Delay Enable

Cmd Loc

007

Default

1

Range

1 - 2

 

 

Comments

Options:

If enabled, the exit delay (Block 2, CL 003) will start when a

1

No

user presses and holds the [Home] key for two seconds. If

2

Yes

disabled, the exit delay will be ignored and the system will

 

 

home arm instantly.

 

 

4X Exit Delay Extension Enable

Comments

Options:

Cmd Loc

Default

Range

008

2

1 - 2

If enabled, the exit delay (Block 2, CL 003) will restart if the

1

No

delay zone is faulted a second or subsequent time during

2

Yes

the exit delay. The exit delay may be restarted up to 4 times.

 

 

Chirp-Alert on Exit Fail

Comments

Options:

Cmd Loc

Default

Range

009

2

1 - 2

If enabled, all sounders (internal and external) will chirp for

1

No

three seconds at the start of the entry delay (Block 2, CL

2

Yes

001 or 002).

 

 

Low Battery Arming

Comments

Options:

Cmd Loc

Default

Range

010

2

1 - 2

If enabled, allows the system to be armed even if the back-

1

No

up battery is low.

2

Yes

Keypad Buzzer During Exit Delay

Comments

Options:

Cmd Loc

Default

Range

011

2

1 - 2

If enabled, the keypad buzzer sounds during the exit delay.

1

No

The keypad buzzer rate is faster during the last 10 seconds

2

Yes

of the exit delay.

 

 

Keypad Buzzer During Entry Delay

Cmd Loc

012

Default

2

Range

1 - 2

 

 

Comments

If enabled, the keypad buzzer sounds during the entry de- lay. The keypad buzzer rate is faster during the last 10 seconds of the entry delay.

Options:

1No

2 Yes

Keypad LED Status

Cmd Loc

013

Default

1

Range

1 - 3

 

 

Comments

This option controls the zone and status displays of the LED keypad.

NOTE: The Power and Arm LEDs on all keypads oper- ate the same.

Options:

1Always display arm and zone status

2 Status always on while disarmed. If armed, status displayed for 30 secs.

3 Display arm and zone status for 30 seconds following User Code entry.

Cross-Zoning List

 

 

 

Zones:

1 - 8

 

9 - 16

17 - 24

25 - 32

Cmd Loc

014

 

015

016

017

Default

0

 

0

0

0

Range

0 - 255

 

0 - 255

0 - 255

0 - 255

 

 

 

 

 

 

Comments

If programmed for cross-zoning, any two of the zones listed here must be violated while armed in order for an alarm condition to register.

If the system is divided into areas, both zones in alarm must be within the same area.

NOTE: Fire, delay, and keyswitch zones are ignored if placed on the cross-zone list.

Options:

0

Disabled

 

 

 

1

Zone 1 9 17 25

2

Zone

2

10

18

26

4

Zone

3

11

19

27

8

Zone

4

12

20

28

16

Zone

5

13

21

29

32

Zone

6

14

22

30

64

Zone

7

15

23

31

128

Zone

8

16

24

32

Double-Knock List

Zones:

1 - 8

9 - 16

17 - 24

25 - 32

Cmd Loc

018

019

020

021

Default

0

0

0

0

Range

0 - 255

0 - 255

0 - 255

0 - 255

 

 

 

 

 

Comments

Zones listed here must be violated twice (or any two zones must be faulted) within

a30-second period in order for an alarm condition to register.

If the system is divided into areas, the alarms must be within the same area.

NOTE: Fire, delay, and keyswitch zones are ignored if placed on this list.

Options:

0

Disabled

 

 

1

Zone 1 9 17 25

2

Zone

2

10 18

26

4

Zone

3

11 19

27

8

Zone

4

12 20

28

16

Zone

5

13 21

29

32

Zone

6

14 22

30

64

Zone

7

15 23

31

128

Zone

8

16 24

32

17

Page 21
Image 21
Sierra S5832SG installation instructions Block 3 - Armed System Programming cont