Block 8 - SpreadNet Programming

The SpreadNet Programming Block has a total of 45 Command Locations (CL 001 - 045). The SpreadNet transmitters must be programmed with the SpreadNet Programmer. Refer to the Sierra Reference Manual for additional information.

SpreadNet Channel

Comments

Cmd Loc

Default

Range

001

1

1 - 2

The Spread Spectrum channel used by the system.

SpreadNet Property Code

Cmd Loc 002 003 004 005

Default 0001

Range 0001 - 4048

Comments

Unique Property Code used to identify a transmitter as being part of the system. Program one digit per Cmd Loc.

SpreadNet Zone Transmitter Supervisory Rates (Zones 1 - 32)

Cmd Loc

006

007

008

009

010

011

012

013

Zone #

1

2

3

4

5

6

7

8

Cmd Loc

014

015

016

017

018

019

020

021

Zone #

9

10

11

12

13

14

15

16

Cmd Loc

022

023

024

025

026

027

028

029

Zone #

17

18

19

20

21

22

23

24

Cmd Loc

030

031

032

033

034

035

036

037

Zone #

25

26

27

28

29

30

31

32

Default

1 (All CL)

 

 

 

 

 

 

Range

1 - 4 (All CL)

 

 

 

 

 

Comments

Options:

 

The Supervisory Rate is the time interval

1

Unsupervised, Battery

between transmitter check-ins. A total of

 

status sent hourly

eight consecutive supervisory check-ins

2

30 seconds

must be missed before a supervisory fail-

3

120

seconds

ure is reported.

4

300

seconds

If option 1 is selected, unsupervised transmitters will send battery status hourly, only if they are within range of the receiver. Transmitters which are out of range will not be reported as missing, because they are unsu- pervised.

SpreadNet Keypad Supervisory Rate (Keypads 1 - 8)

Cmd Loc

038

039

 

040

041

042

043

044

045

Keypad #

1

2

 

3

4

5

6

7

8

Default

1

(All CL)

 

 

 

 

 

 

Range

1 -

4 (All CL)

 

 

 

 

 

 

Block 9 - Partition (Area) Programming

This Block has 178 Command Locations (CL 001 - 178) and is used to define all partition information, including which zones, user codes, and keypads are assigned to each partition. SpreadNet SN991-REMOTEs and SN961-KEYFOBs are associated with a specific user number and both sections must be programmed for them to function.

Partition Type

Cmd Loc 001

Default 1

Range 1 - 3

Comments

This option is used to specify whether or not a partitioned system has a common area and the type of display used in the common area.

Options:

1No Common Area

2Common Area - Full View Keypad

3Common Area - Limited View Keypad

Zone Assignments to Areas (Zones 1 - 32)

 

Comments

Cmd Loc

002

003

004

005

006

007

008

009

Each zone may be individually assigned to an

Zone #

1

2

3

4

5

6

7

8

Area (Partition) or disabled.

Cmd Loc

010

011

012

013

014

015

016

017

 

Zone #

9

10

11

12

13

14

15

16

 

Cmd Loc

018

019

020

021

022

023

024

025

 

Zone #

17

18

19

20

21

22

23

24

 

Cmd Loc

026

027

028

029

030

031

032

033

 

Zone #

25

26

27

28

29

30

31

32

 

Default

1 (All CL)

 

 

 

 

 

 

 

Range

0 - 8 (All CL)

 

 

 

 

 

 

Options:

0Zone Disabled

1 Area 1

2 Area 2

3 Area 3

4 Area 4

5 Area 5

6 Area 6

7 Area 7

8 Area 8

35

Page 39
Image 39