Output Terminals
Table 3 shows the Output Terminals of the S5832SG, with the Voltage and Current Range of each Output. The Table also shows the maximum combined current for related out- puts.
|
| Voltage |
| Combined |
| |
Function | Terminal | Range | Current | Current | Comments | |
Strobe |
|
|
|
| Specifically designed to | |
STROBE | 8.4 – 14.9 V | 0.75 A |
| drive strobes with high | ||
Output |
| |||||
|
|
|
| |||
|
|
|
|
| ||
Internal | INT |
|
|
| Typically used to drive | |
8.4 – 14.9 V | 0.75 A |
| sirens mounted inside | |||
Siren | SIREN |
| ||||
|
|
| the premises. | |||
|
|
|
|
| ||
|
|
|
|
| Supervised Siren Output | |
External | BELL+ |
|
|
| typically used to drive | |
8.4 – 14.9 V | 2.0 A |
| bells, sirens, and other | |||
Siren | BELL- |
| ||||
|
| 1.5 A | high current devices | |||
|
|
|
| |||
|
|
|
| outside the premises. | ||
|
|
|
| (3.0 A with | ||
|
|
|
| Battery) |
| |
Auxiliary | AUX | 8.4 – 14.9 V | 1.0 A | Used to drive sensors, | ||
| ||||||
Power |
| etc. | ||||
|
|
|
| |||
|
|
|
|
| Used to drive latching | |
Switched |
|
|
|
| devices like glassbreak | |
Auxiliary | SW AUX | 8.4 – 14.9 V | 0.3 A |
| detectors or | |
Power |
|
|
|
| smoke detectors that | |
|
|
|
|
| must be reset. | |
Keypad |
|
|
|
| Used to power keypads, | |
KPWR | 8.4 – 14.9 V | 1.0 A |
| REMMs, ZEMs, and | ||
Power |
| |||||
|
|
|
| SN915 RF Receiver. | ||
|
|
|
|
| ||
|
|
|
|
|
| |
Zone 8 | Z8 | 8.5 – 14.0 V | 0.03 A | 0.03 A |
Table 3
Output Terminal limits
External Bell Supervision
The circuit connection shown in Figure 5 is used only when External Bell Line Super-
vision is required. For Bell Line Supervision, the bell must be equipped with an internal diode.
To Bell Output Terminals
on Control Panel
Figure 5 - Bell Supervision Wiring
Keypad Wiring
The Sierra S5832SG uses four terminals for powering and communicating with the keypads and other devices via the keypad data bus. The terminal connections are as follows:
KPWR This terminal supplies +12 VDC to power the key- pads or accessories.
KY+ One half of the differential keypad data bus. This terminal combined with the KY- terminal provides communication between the various devices and the control panel.
KY- Used in conjunction with the KY+ terminal for data communications on the keypad data bus.
CCommon (ground) terminal for Power return. TRMX Optional Terminate Exit Delay switch connected
between this terminal and C terminal. When active (Block 7, CL 012), closing the exit delay switch will short the TRMX terminal and skip all but the last 5 seconds of the exit delay.
Keypad Wiring (cont.)
Figure 6, below, shows the connections for wiring the Sierra Keypad to the Control Panel and connecting the optional Terminate Exit Delay switch. Switch S1, in the lower right- hand corner, is used for keypad addressing (see Table 5).
NOTE: If the keypad tampers are active (and programmed in Block 3, Cmd Loc 044 - 045), tamper signals will be sent to the control panel via the keypad bus. Keypad tamper (hardwired keypads only) report routing is programmed in Block 4, Cmd Loc 158. Keypad trouble conditions are also reported on the keypad bus and the routing is defined in Block 4, Cmd Loc 159.
Optional Terminate
Exit Delay Switch
Tamper Switch
Figure 6
Connecting the Keypad Terminals
Sierra Accessory Wiring Distances
The Table shown below shows the maximum wiring dis- tances for the Sierra accessories based upon total load cur- rent drawn from each run. Refer to the Accessory Loading Table on page 3 for load requirements.
NOTE: Total wire distance for all devices combined not to exceed 2440 M.
Max Load | 0.40 mm | 0.51 mm | 0.64 mm | 0.81 mm | 1.02 mm | 1.29 mm | ||||||
per run | (26 AWG) | (24 AWG) | (22 AWG) | (20 AWG) | (18 AWG) | (16 AWG) | ||||||
(mA) | M | (Ft.) | M | (Ft.) | M | (Ft.) | M | (Ft.) | M | (Ft.) | M | (Ft.) |
50 | 121 | (395) | 192 | (629) | 305 (1000) | 490 (1605) | 774 (2538) | 1225 | (4016) | |||
|
|
|
|
|
|
|
|
|
|
|
| |
100 | 60 | (198) | 96 | (314) | 153 | (500) | 245 | (803) | 387 (1269) | 612 | (2008) | |
|
|
|
|
|
|
|
|
|
|
|
|
|
150 | 40 | (132) | 64 | (210) | 102 | (333) | 163 | (535) | 258 | (846) | 408 | (1339) |
200 | 30 | (99) | 48 | (157) | 76 | (250) | 122 | (401) | 194 | (635) | 306 | (1004) |
250 | 24 | (79) | 38 | (126) | 61 | (200) | 98 | (321) | 155 | (508) | 245 | (803) |
300 | 20 | (66) | 32 | (105) | 51 | (167) | 82 | (268) | 129 | (423) | 204 | (669) |
|
|
|
|
|
|
|
|
|
|
|
|
|
350 | 17 | (56) | 27 | (90) | 44 | (143) | 70 | (229) | 111 | (363) | 175 | (574) |
|
|
|
|
|
|
|
|
|
|
|
|
|
400 | 15 | (49) | 24 | (79) | 38 | (125) | 61 | (201) | 97 | (317) | 153 | (502) |
450 | 13 | (44) | 21 | (70) | 34 | (111) | 54 | (178) | 86 | (282) | 136 | (446) |
500 | 12 | (40) | 19 | (63) | 31 | (100) | 49 | (161) | 77 | (254) | 122 | (402) |
|
|
|
|
|
|
|
|
|
|
|
|
|
550 | 11 | (36) | 17 | (57) | 28 | (91) | 45 | (146) | 70 | (231) | 111 | (365) |
600 | 10 | (33) | 16 | (52) | 25 | (83) | 41 | (134) | 65 | (212) | 102 | (335) |
700 | 9 | (28) | 14 | (45) | 22 | (71) | 35 | (115) | 55 | (181) | 87 | (287) |
|
|
|
|
|
|
|
|
|
|
|
|
|
800 | 8 | (25) | 12 | (39) | 19 | (63) | 31 | (100) | 48 | (159) | 77 | (251) |
|
|
|
|
|
|
|
|
|
|
|
|
|
900 | 6 | (22) | 10 | (35) | 17 | (55) | 27 | (89) | 43 | (141) | 68 | (223) |
|
|
|
|
|
|
|
|
|
|
|
|
|
1000 | 6 | (20) | 9 | (31) | 15 | (50) | 24 | (80) | 39 | (127) | 61 | (201) |
Table 4
Maximum Wiring Distance for Sierra Accessories