Block 4 - Digital Communicator Programming (cont.)
RPS Callback Enable | Comments | ||
|
|
| If enabled, requires the panel to call COMMANDER II in |
Cmd Loc | 105 |
| |
Default | 1 |
| order to establish RPS. If disabled, the panel will stay |
Range | 1 - 2 |
| when called by COMMANDER II the second time (following |
|
|
| handshaking). |
|
|
|
Options:
1No
2 Yes
Keypad RPS Enable | Comments | ||
Cmd Loc | 106 |
| If enabled, allows remote programming to be initiated from |
Default | 2 |
| the keypad (either Block 0 or user programming). |
Range | 1 - 2 |
|
|
|
|
|
|
Options:
1No
2 Yes
RPS and | Comments | Options: |
Cmd Loc
Default
Range
107
2
1 - 2
Establishes the modem protocol for RPS and | 1 | Bell 103 |
communications. | 2 | CCITT |
Alarm Dialing Delay (Seconds) | Comments |
Cmd Loc
Default
Range
108
0
0 - 255
The delay (in seconds) after an alarm occurs before the report is sent.
| Comments | Options: |
Cmd Loc
Default
Range
109
1
1 - 2
If enabled, uses the time programmed above (Block 4, CL | 1 | No |
108) for reporting alarms on | 2 | Yes |
hour zones report immediately. |
|
|
Cancel Report Delay (Seconds) | Comments |
Cmd Loc
Default
Range
110
0
0 - 255
The amount of time (in seconds), following an alarm, during which a cancel report may be sent. The cancel report is not sent if a valid user code is entered before the alarm dialing delay has expired.
Dialer Retry Sequence
Cmd Loc | 111 |
Default | 4 |
Range | 1 - 4 |
|
|
Options:
1Repeat Call Attempt
Series Every 30 min.
2Repeat Call Attempt Series Every four hrs.
3Repeat Call Attempt Series at 30 min.
then double interval up to 128 hrs.
4No additional Call Attempts After Failed Series Until New Report is Queued.
Phone Line Call Routing
Cmd Loc 112
Default 1
Range 1 - 4
Options:
1Line #1 Only
2Line #1 with Line #2 Backup (Phone Line Cut or Comm Fail)
3Line #1 with Line #2 as Backup, Alternating (2 Attempts Each)
4Line #1 with Line #2 as Backup, Alternating (4 Attempts Each)
Test Report Interval (Days) | Comments |
Cmd Loc
Default
Range
113
7
0 - 30
This option determines the test interval. Test reports are sent in daily intervals, ranging from 1 to 30 days. The time of day for the report is programmed into Block 4, CL 114. To disable reporting, set to 0.
Test Report Time of Day (Hours) | Comments |
Cmd Loc
Default
Range
114
1
0 - 23
When programming the test report time of day, use the
Ringback Outputs Enable | Comments | Options: |
Cmd Loc
Default
Range
115
0
0 - 15
The selected outputs will sound for three sec- | 0 | Disable |
onds following a successful closing report. | 1 | Keypad Buzzer |
| 2 | Strobe |
| 4 | Internal Siren |
| 8 | External Bell |
23