Exit Delay Terminator

Cmd Loc 012

Default 1

Range 1 - 2

Block 7 - Auxiliary Devices Programming (cont.)

Comments

Options:

If enabled, jumps to the last 5 seconds of the exit delay,

1

No

then arms the system. Requires a normally open switch

2

Yes

connected to keypad (TXD and C terminals).

 

 

Timer Units (On Board Relay)

Cmd Loc 013

Default 2

Range 1 - 5

Timer Count (On Board Relay)

Cmd Loc

014

Default

30

Range

1 - 255

Timer Units (REMM #1, Relay #1)

Cmd Loc 015

Default 2

Range 1 - 5

Timer Count (REMM #1, Relay #1)

Cmd Loc

016

Default

30

Range

1 - 255

Timer Units (REMM #1, Relay #2)

Cmd Loc 017

Default 2

Range 1 - 5

Timer Count (REMM #1, Relay #2)

Cmd Loc 018

Default 30

Range 1 - 255

Timer Units (REMM #1, Relay #3)

Cmd Loc 019

Default 2

Range 1 - 5

Timer Count (REMM #1, Relay #3)

Cmd Loc

020

Default

30

Range

1 - 255

Timer Units (REMM #1, Relay #4)

Cmd Loc 021

Default 2

Range 1 - 5

Timer Count (REMM #1, Relay #4)

Cmd Loc

022

Default

30

Range

1 - 255

Timer Units (REMM #1, Relay #5)

Cmd Loc 023

Default 2

Range 1 - 5

Timer Count (REMM #1, Relay #5)

Cmd Loc

024

Default

30

Range

1 - 255

Comments

Options:

Each relay has its own independent countdown timer.

1

Latched

The timer consists of two parts: the Units and the Counter.

2

Seconds

The countdown timer determines the amount of time a

3

Minutes

relay will remain closed. For the On-Board Relay, CL 013

4

Hours

stores the units, while CL 014 stores the starting count.

5

Days

The timer will count backwards and when it reaches 0,

 

 

the respective relay will open.

 

 

NOTE: The timer function is ignored if the Relay option (Block 7, CL 001 -

011)is programmed for SpreadNet Arming/Disarming (option #5), Listen-In Trigger (option #9), Follows Keypad Sounder (option #10), Relay Status #1 (option #67), Relay Status #2 (option #68), 3-second Toggle for Audible Shutoff (option #72), or 3-second Toggle for Local Bell Test (option #73).

Comments

For REMM #1, Relay #1, CL 015 stores the units, while CL 016 stores the starting count. The timer will count backwards and when it reaches 0, the respective relay will open.

Comments

For REMM #1, Relay #2, CL 017 stores the units, while CL 018 stores the starting count. The timer will count backwards and when it reaches 0, the respective relay will open.

Comments

For REMM #1, Relay #3, CL 019 stores the units, while CL 020 stores the starting count. The timer will count backwards and when it reaches 0, the respective relay will open.

Comments

For REMM #1, Relay #4, CL 021 stores the units, while CL 022 stores the starting count. The timer will count backwards and when it reaches 0, the respective relay will open.

Comments

For REMM #1, Relay #5, CL 023 stores the units, while CL 024 stores the starting count. The timer will count backwards and when it reaches 0, the respective relay will open.

32

Page 36
Image 36
Sierra S5832SG installation instructions Exit Delay Terminator, Timer Units On Board Relay, Timer Count On Board Relay