Sierra Programming Summary - Sierra Model S5832SG, Block 1 - Code Option Programming

Models: S5832SG

1 44
Download 44 pages 10.6 Kb
Page 17
Image 17
Programming Summary - Sierra Model S5832SG

Programming Summary - Sierra Model S5832SG

Block 1 - Code Option Programming

This programming block is divided into 80 Command Locations (CL 001 - 080). This Block used to program the Installer’s Code (001-006), Default Installer Code on Power Up (007), Require Installer Code for Direct Connect via RPS (008), and to set up the User Code parameters. The parameters include setting Maid Code, Duress, and Kidwatch.

Installer Code

Cmd Loc

001

002

003

004

005

006

Default

0

1

2

3

4

5

Range

0 - 9

0 - 9

0 - 9

0 - 9

0 - 9

0 - 9

 

 

 

 

 

 

 

Comments

This is a 6-digit code which is required to allow access to installer program- ming mode. The code is programmed 1 digit per Cmd Loc.

Default Installer Code on Power Up?

Comments

Options:

Cmd Loc

Default

Range

007

2

1 - 2

If enabled (programmed as 2), this restores the Installer

1

No

Code to the default value (see CL 001 - 006) following a

2

Yes

power failure/restoral.

 

 

Installer Code Required on Direct Connect RPS?

Comments

Options:

Cmd Loc

008

 

If enabled, the Installer Code (CL 001 - 006) is required

1

No

Default

2

 

when programming the panel with the direct connect RPS

2

Yes

Range

1 - 2

 

function of COMMANDER II.

 

 

 

 

 

 

 

 

Maid Code Enable (by Area)

 

 

 

 

Comments

Options:

Cmd Loc

009

010

011

012

013

014

015

016

The Maid Code may be specified by active days of

0

Disabled

Default

0

0

0

0

0

0

0

0

the week and by individual areas. Area 1 may also

1

Saturday

Area

1

2

3

4

5

6

7

8

use keypad activation for temporary access.

2

Friday

Range

0 - 255 (CL 009)

 

 

 

 

NOTE: Maid Code Enable programming deter-

4

Thursday

 

0 - 127 (CL 010 - 016)

 

 

 

8

Wednesday

 

 

 

 

 

 

 

 

 

mines when the Maid Code may be used for disarm-

16

Tuesday

 

 

 

 

 

 

 

 

 

ing the system. The Maid code is always available to

32

Monday

 

 

 

 

 

 

 

 

 

arm the system.

64

Sunday

 

 

 

 

 

 

 

 

 

 

128

By Keypad

 

 

 

 

 

 

 

 

 

 

 

 

Maid Code Hours, Temporary Access, Area 1

Comments

 

 

Cmd Loc

Default

Range

017

12

0 - 254

This option is used in conjunction with keypad activation of the Maid Code for area 1 only. Duration of the active period is from the time of activation by grand master user (user #1) or area master (user #12). To disable keypad (temporary) activation, program this location with 0.

Duress Code Enable (By Area)

Cmd Loc

018

Default

0

Range

0 - 255

 

 

Comments

Options:

If the system is divided into areas, this option deter-

0

Disabled

mines if the duress code associated with a specific

1

Area 1

area is active. Refer to the Sierra S5090 Reference

2

Area 2

Manual (P/N 5-051-528-01), Block 9 programming

4

Area 3

for details on assigning user codes to areas.

8

Area 4

 

16

Area 5

 

32

Area 6

 

64

Area 7

 

128

Area 8

Kidwatch Enable

Cmd Loc

019

Default

0

Range

0, 129 - 255

 

 

Comments

Options:

If used, this option must be enabled (program

0

Disabled

value > 128) and have the appropriate days of

1

Saturday

the week programmed. The Kidwatch timer is

2

Friday

programmed from Block 6, CL 006 - 009. The

4

Thursday

same start and end times are used for all days

8

Wednesday

when the Kidwatch feature is active.

16

Tuesday

NOTE: If enabled, the Kidwatch code must be

32

Monday

64

Sunday

entered if Area 1 is armed during the Kidwatch

128

Enable (Master)

window (see Block 6, CL 006 - 009).

 

 

Keypad Lockout Enable

Comments

Options:

Cmd Loc

Default

Range

020

1

1 - 3

If enabled, 10 consecutive keystrokes without pro-

1

Disabled

ducing a valid user code will cause a keypad

2

When Disarmed

delay starting at 15 seconds and doubling each

3

Always Active

time up to a maximum of 240 seconds (4 min).

 

 

13

Page 17
Image 17
Sierra installation instructions Programming Summary - Sierra Model S5832SG, Block 1 - Code Option Programming