Block 3 - Armed System Programming (cont.)

Keypad Tamper Switch Enable (By Address)

Keypad #

1 - 8

9 - 16

Cmd Loc

044

045

Default

0

0

Range

0 - 255

0 - 255

 

 

 

Comments

Each Cmd Loc will be programmed with the total of the keypad addresses with ac- tive tamper switches.

Keypad Tampers are reported via the keypad bus.

Options:

0

Disabled

 

 

1

Keypad

1

9

2

Keypad

2

10

4

Keypad

3

11

8

Keypad

4

12

16

Keypad

5

13

32

Keypad

6

14

64

Keypad

7

15

128

Keypad

8

16

Reserved for Future Use

Comments

Cmd Loc

046

047

 

 

These locations are Reserved for Future Use and are not available in this

Default

0

0

 

 

firmware version.

Range

N/A

N/A

 

 

 

 

 

 

 

 

External Bell Reverse Enable

Comments

Options:

Cmd Loc

048

 

If enabled, supplies voltage to external bell when bell is off.

1

No

Default

1

 

This option may not be used with External Bell Supervision

2

Yes

Range

1 - 2

 

(Block 3, CL 043) enabled.

 

 

 

 

 

 

 

 

Sounder (Bell) Test Enable (By Area)

Comments

Cmd Loc

049

 

Sounds a 5-second bell test at the start of each exit

Default

0

 

delay. The value programmed into this Cmd Loc is the

Range

0 - 255

 

total of all areas for which the bell test will be active.

 

 

 

 

Options:

0Disabled

1 Area 1

2 Area 2

4 Area 3

8 Area 4

16Area 5

32Area 6

64Area 7

128 Area 8

Home Arming Enable

Comments

Options:

Cmd Loc

050

 

This option, when enabled, allows a system to be home

1

No

Default

1

 

armed or instant home-armed. All zones listed in the

2

Yes

Range

1 - 2

 

Home Arm Bypass List (Block 2, CL 151 - 154) will be

 

 

 

 

 

automatically bypassed.

 

 

 

 

 

 

 

Keyswitch/SpreadNet Arming Annunciation

Comments

Options:

Cmd Loc

051

 

This option determines how keyswitch or

0

No Annunciation

Default

0

 

SpreadNet arming is annunciated. The value

1

Keypad Buzzer

Range

0 - 15

 

programmed into this Cmd Loc is the total of

2

Strobe

 

 

 

all sounders to be activated. When arming,

4

Internal Siren

 

 

 

 

 

 

the selected sounders will beep three times

8

External Bell

 

 

 

(1.5 sec on/off) and the strobe will light for 3

 

 

 

 

 

seconds. When disarming, the selected

 

 

 

 

 

sounders will beep once and the strobe will

 

 

 

 

 

be on for 1.5 seconds.

 

 

Auto-Arming Enable (Day of Week)

Comments

Options:

Cmd Loc

052

 

This will automatically arm the areas specified in

0

Disabled

Default

0

 

Block 3, CL 022 at the time specified in Block 3,

1

Saturday

Range

0 - 127

 

CL 023 and 024. The value programmed here is

2

Friday

 

 

 

the total for all days of the week when the system

4

Thursday

 

 

 

 

 

 

will auto-arm.

8

Wednesday

 

 

 

 

16

Tuesday

 

 

 

 

32

Monday

 

 

 

 

64

Sunday

 

 

 

 

Ground Fault Supervision Enable

Comments

 

Options:

Cmd Loc

Default

Range

053

1

1 - 2

This option, when enabled, reports and annunciates all

1

No

ground fault conditions.

2

Yes

When disabled, these conditions are not reported or annunciated.

20

Page 24
Image 24
Sierra S5832SG installation instructions Keypad Tamper Switch Enable By Address Keypad #, Reserved for Future Use Comments