Block 3 - Armed System Programming (cont.)
Keypad Tamper Switch Enable (By Address)
Keypad # | 1 - 8 | 9 - 16 |
Cmd Loc | 044 | 045 |
Default | 0 | 0 |
Range | 0 - 255 | 0 - 255 |
|
|
|
Comments
Each Cmd Loc will be programmed with the total of the keypad addresses with ac- tive tamper switches.
Keypad Tampers are reported via the keypad bus.
Options:
0 | Disabled |
|
|
1 | Keypad | 1 | 9 |
2 | Keypad | 2 | 10 |
4 | Keypad | 3 | 11 |
8 | Keypad | 4 | 12 |
16 | Keypad | 5 | 13 |
32 | Keypad | 6 | 14 |
64 | Keypad | 7 | 15 |
128 | Keypad | 8 | 16 |
Reserved for Future Use | Comments | |||
Cmd Loc | 046 | 047 |
| |
| These locations are Reserved for Future Use and are not available in this | |||
Default | 0 | 0 |
| |
| firmware version. | |||
Range | N/A | N/A |
| |
|
| |||
|
|
|
|
|
External Bell Reverse Enable | Comments | Options: | |||
Cmd Loc | 048 |
| If enabled, supplies voltage to external bell when bell is off. | 1 | No |
Default | 1 |
| This option may not be used with External Bell Supervision | 2 | Yes |
Range | 1 - 2 |
| (Block 3, CL 043) enabled. |
|
|
|
|
|
|
|
|
Sounder (Bell) Test Enable (By Area) | Comments | ||
Cmd Loc | 049 |
| Sounds a |
Default | 0 |
| delay. The value programmed into this Cmd Loc is the |
Range | 0 - 255 |
| total of all areas for which the bell test will be active. |
|
|
|
|
Options:
0Disabled
1 Area 1
2 Area 2
4 Area 3
8 Area 4
16Area 5
32Area 6
64Area 7
128 Area 8
Home Arming Enable | Comments | Options: | |||
Cmd Loc | 050 |
| This option, when enabled, allows a system to be home | 1 | No |
Default | 1 |
| armed or instant | 2 | Yes |
Range | 1 - 2 |
| Home Arm Bypass List (Block 2, CL 151 - 154) will be |
|
|
|
|
| automatically bypassed. |
|
|
|
|
|
|
|
Keyswitch/SpreadNet Arming Annunciation | Comments | Options: | |||
Cmd Loc | 051 |
| This option determines how keyswitch or | 0 | No Annunciation |
Default | 0 |
| SpreadNet arming is annunciated. The value | 1 | Keypad Buzzer |
Range | 0 - 15 |
| programmed into this Cmd Loc is the total of | 2 | Strobe |
|
|
| all sounders to be activated. When arming, | 4 | Internal Siren |
|
|
| |||
|
|
| the selected sounders will beep three times | 8 | External Bell |
|
|
| (1.5 sec on/off) and the strobe will light for 3 |
|
|
|
|
| seconds. When disarming, the selected |
|
|
|
|
| sounders will beep once and the strobe will |
|
|
|
|
| be on for 1.5 seconds. |
|
|
| Comments | Options: | |||
Cmd Loc | 052 |
| This will automatically arm the areas specified in | 0 | Disabled |
Default | 0 |
| Block 3, CL 022 at the time specified in Block 3, | 1 | Saturday |
Range | 0 - 127 |
| CL 023 and 024. The value programmed here is | 2 | Friday |
|
|
| the total for all days of the week when the system | 4 | Thursday |
|
|
| |||
|
|
| will | 8 | Wednesday |
|
|
|
| 16 | Tuesday |
|
|
|
| 32 | Monday |
|
|
|
| 64 | Sunday |
|
|
|
| ||
Ground Fault Supervision Enable | Comments |
| Options: |
Cmd Loc
Default
Range
053
1
1 - 2
This option, when enabled, reports and annunciates all | 1 | No |
ground fault conditions. | 2 | Yes |
When disabled, these conditions are not reported or annunciated.
20