Block 1 - Code Option Programming (cont.)

Block 1 - Code Option Programming (cont.)

User Code Privileges (User # 1 - 60)

 

 

Comments

 

 

Options:

Cmd Loc

 

021

022

 

023

024

025

026

027

028

These programming Options determine which

0

Limited Functions**

User #

 

1

2

 

3

4

5

6

7

8

Options the user is authorized to perform.

1

Disarm

Cmd Loc

 

029

030

 

031

032

033

034

035

036

Some user codes may have alternate func-

2

Arm

User #

 

9

10

 

11

12

13

14

15

16

tions. (See Block 9 - Partition Programming

4

Bypass

Cmd Loc

 

037

038

 

039

040

041

042

043

044

in the Sierra Reference Manual for additional

8

Open/Close Rpt

User #

 

17

18

 

19

20

21

22

23

24

information.)

 

 

 

 

Cmd Loc

 

045

046

 

047

048

049

050

051

052

 

 

 

 

16

Lang. Code opt. 1

User #

 

25

26

 

27

28

29

30

31

32

 

Language

Program Value

 

32

Lang. Code opt. 2

Cmd Loc

 

053

054

 

055

056

057

058

059

060

 

 

 

 

 

 

 

 

 

English

0

 

 

 

User #

 

33

34

 

35

36

37

38

39

40

 

 

 

 

 

 

 

Spanish

16

 

 

 

Cmd Loc

 

061

062

 

063

064

065

066

067

068

 

 

 

 

 

 

 

 

 

 

 

 

User #

 

41

42

 

43

44

45

46

47

48

 

Italian

32

 

 

 

Cmd Loc

 

069

070

 

071

072

073

074

075

076

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User #

 

49

50

 

51

52

53

54

55

56

 

 

** Limited Functions are user number specific.

Cmd Loc

 

077

078

 

079

080

 

 

 

 

 

 

They may include relay operation, restricted

User #

 

57

58

 

59

60

 

 

 

 

 

 

SN device operation, and some end-user

Default

 

15 (All CL)

 

 

 

 

 

 

 

 

functions.

 

 

Range

0 - 47 (All CL)

 

 

 

 

 

 

 

 

 

 

 

 

Block 2 - Zone Configuration Programming

Block 2 is divided into 160 Command Locations (CL 001 - 160) which are used to program the characteristics of each of the zones in the control panel. The features include Delay Times, Zone Type, Zone Restoral Type, Zone Response Time, Audible Cadence, Circuit Type, Chime Enable, Shunt Enable, and Home Arm Shunt List. The soft zone programming uses CL 155 - 160.

Entry Delay #1

Cmd Loc

001

Default

20

Range

10 - 255 (Seconds)

 

 

Comments

This establishes the first of two delay times for entry zones. Time is entered in seconds.

Entry Delay #2

Cmd Loc

002

Default

40

Range

10 - 255 (Seconds)

 

 

Comments

This establishes the second of two delay times for entry zones. Time is entered in seconds.

Exit Delay

Cmd Loc

003

Default

60

Range

20 - 255 (Seconds)

 

 

Comments

This establishes the delay time for exit zones. The time programmed into this location should allow the user to use the exit farthest from the keypad. Time is entered in seconds.

Zone Type (Zones 1 - 32)

Cmd Loc

004

005

006

007

008

009

010

011

Zone #

1

 

2

3

4

5

6

7

8

Default

1

 

3

3

5

5

5

5

10

Cmd Loc

012

013

014

015

016

017

018

019

Zone #

9

 

10

11

12

13

14

15

16

Cmd Loc

020

021

022

023

024

025

026

027

Zone #

17

 

18

19

20

21

22

23

24

Cmd Loc

028

029

030

031

032

033

034

035

Zone #

25

 

26

27

28

29

30

31

32

Default

0

(CL 012 - 035)

 

 

 

 

Range

0 - 15 (All CL)

 

 

 

 

 

Comments

Options:

 

 

These programming

0

Disabled

8

Day Bell/Inst

Options determine the

1

Entry Delay 1/Exit

9

Day Bell/Delay

zone type for each zone

2

Entry Delay 2/Exit

10

24-Hr. BA

(hardwired or wireless)

3

Interior Instant

11

Fire (FA)

in the system.

4

Interior Delay 2

12

Tamper

 

5

Instant (Perim.)

13

Panic/Hold-Up

 

6

Day Buzzer/Inst

14

Emergency-Med

7Day Buzzer/Delay 15 Keyswitch **

**If the Zone Type is programmed as Keyswitch, then Zone Restoral Type (Block 2, CL 036 - 067) will be programmed using Option #2 values.

Zone Restoral Type (Zones 1 - 32)

Cmd Loc

036

037

038

039

040

041

042

043

Zone #

1

2

3

4

5

6

7

8

Cmd Loc

044

045

046

047

048

049

050

051

Zone #

9

10

11

12

13

14

15

16

Cmd Loc

052

053

054

055

056

057

058

059

Zone #

17

18

19

20

21

22

23

24

Cmd Loc

060

061

062

063

064

065

066

067

Zone #

25

26

27

28

29

30

31

32

Default

2 (All CL)

 

 

 

 

 

 

Range

1 - 5 (All CL)

 

 

 

 

 

Comments

Option #1 values are used for all zone types except Keyswitch.

Keyswitch zones will use the second set of Options. Default value for keyswitch is 2 (Arm/Disarm).

Option Set #1

Option Set #2

1

Disabled

1

Disabled

2

Return to normal

2

Arm/Disarm

3

Return to normal

3

Arm Only

 

and bell silenced

4

Disarm Only

4

Return to normal

5

N/A

 

and not armed

 

 

5User code entry (zone may remain faulted)

14

Page 18
Image 18
Sierra S5832SG installation instructions Block 1 - Code Option Programming cont, Block 2 - Zone Configuration Programming