Block 7 - Auxiliary Devices Programming

The Auxiliary Devices Programming Block has a total of 79 Command Locations (CL 001 - 079). Each of the first 11 commands has an input range of 1 - 82. Additional relay Options are provided for setting up specific timing operations.

On Board Relay

Cmd Loc 001

Default 1

Range 1 - 82

Relay #1 - REMM #1

Cmd Loc 002

Default 1

Range 1 - 82

Relay #2 - REMM #1

Cmd Loc 003

Default 1

Range 1 - 82

Relay #3 - REMM #1

Cmd Loc 004

Default 1

Range 1 - 82

Relay #4 - REMM #1

Cmd Loc 005

Default 1

Range 1 - 82

Relay #5 - REMM #1

Cmd Loc 006

Default 1

Range 1 - 82

Relay #1 - REMM #2

Cmd Loc 007

Default 1

Range 1 - 82

Relay #2 - REMM #2

Cmd Loc 008

Default 1

Range 1 - 82

Relay #3 - REMM #2

Cmd Loc 009

Default 1

Range 1 - 82

Relay #4 - REMM #2

Cmd Loc 010

Default 1

Range 1 - 82

Relay #5 - REMM #2

Cmd Loc 011

Default 1

Range 1 - 82

Options:

1 Disabled, relay open

2Close on SN “Door” button (keypad or re- mote) activation

3 Closed when entire system armed

4 Closed when entire system disarmed

50.5 sec on/off (3x) when keyswitch or Spread- Net arming; 1.5 sec on for keyswitch or SpreadNet disarming (ignores timer)

6 Close on any tamper

7 Close when phone line cut

8 Close when comm fail occurs

93-sec toggle to activate listen-in (ignores timer)

10 Follow keypad audible sounder (exit/entry de- lays, area 1 only) (ignores timer)

11 Close on fault (except 24-hr. zone); open when faulted zone is bypassed, restored, system armed, or timer

12 Close on any alarm

13 Close on fire alarm

14 Close on burglar alarm

15 Close on panic/holdup

16 Close in installer programming mode

17 Activated by Commander II (RPS)

18 Close at end of exit delay (all areas armed), open at start of entry delay

19 Close on area 1 alarm

20 Close on area 2 alarm

21 Close on area 3 alarm

22 Close on area 4 alarm

23 Close on area 5 alarm

24 Close on area 6 alarm

25 Close on area 7 alarm

26 Close on area 8 alarm

27 Close when area 1 armed

28 Close when area 2 armed

29 Close when area 3 armed

30 Close when area 4 armed

31 Close when area 5 armed

32 Close when area 6 armed

33 Close when area 7 armed

34 Close when area 8 armed

35 Close when armed, oscillate at 0.5 Hz when home armed (area 1)

36 Close when armed, oscillate at 0.5 Hz when home armed (area 2)

37 Close when armed, oscillate at 0.5 Hz when home armed (area 3)

38 Close when armed, oscillate at 0.5 Hz when home armed (area 4)

39 Close when armed, oscillate at 0.5 Hz when home armed (area 5)

40 Close when armed, oscillate at 0.5 Hz when home armed (area 6)

41 Close when armed, oscillate at 0.5 Hz when home armed (area 7)

42 Close when armed, oscillate at 0.5 Hz when home armed (area 8)

43Close on relay user code 14 entry

44Close on relay user code 18 entry

45Close on relay user code 22 entry

46Close on relay user code 26 entry

47Close on relay user code 30 entry

48Close on relay user code 34 entry

49Close on relay user code 38 entry

50Close on relay user code 42 entry

51Close on user code entry (area 1)

52Close on user code entry (area 2)

53Close on user code entry (area 3)

54Close on user code entry (area 4)

55Close on user code entry (area 5)

56Close on user code entry (area 6)

57Close on user code entry (area 7)

58Close on user code entry (area 8)

59Close on duress (area 1), open on next area 1 user code entry (except Duress code)

60Close on duress (area 2), open on next area 2 user code entry (except Duress code)

61Close on duress (area 3), open on next area 3 user code entry (except Duress code)

62Close on duress (area 4), open on next area 4 user code entry (except Duress code)

63Close on duress (area 5), open on next area 5 user code entry (except Duress code)

64Close on duress (area 6), open on next area 6 user code entry (except Duress code)

65Close on duress (area 7), open on next area 7 user code entry (except Duress code)

66Close on duress (area 8), open on next area 8 user code entry (except Duress code)

67Relay status #1 (see below) (ignores timer)

68Relay status #2 (see below) (ignores timer)

69Close on bell supervision trouble

70Close on keypad/accessory trouble or tamper

71Close on Medical alarm

723-sec toggle for annunciator shutoff (ignores timer)

733-sec toggle on local bell test (ignores timer)

74Close on alarm associated with zone activated relay (see Block 7, CL 035 - 066)

75Close on AC fail

76Close on low battery

77Close on chime zone fault

78Close on system trouble

79Close on Pre-set Timer #1 (Block 7, CL 067 - 069)

80Close on Pre-set Timer #2 (Block 7, CL 070 - 072)

81Close on Pre-set Timer #3 (Block 7, CL 073 - 075)

82Close on Pre-set Timer #4 (Block 7, CL 076 - 078)

NOTE: All relays may be programmed to open ac- cording to a timer (Block 7, CL 013 - 034), unless otherwise indicated. For additional information, refer to the S5090 Reference Manual.

Relay status #1

 

 

Relay status #2

 

 

 

 

 

 

 

 

 

System Status

Alarms?

Relay State

System Status

 

Alarms?

Relay State

Disarmed

No

Closed

Disarmed

 

No

Open

Disarmed

Yes

Open

Disarmed

 

Yes

Open

Armed

No

Closed

Armed

 

No

Closed

Armed

Yes

Open

Armed

 

Yes

Open

NOTE: Relays are open when de-energized.