3REC (record) INHIBIT switch
When this switch is set to ON, the REC INHIBIT indicator in the display section lights, and recording on tape is no longer possible. (See the description of extended menu item 107.)
4KEY INHIBIT switch
When this switch is set to ON, the KEY INHIBIT indicator in the display section lights, and the buttons in the upper control panel and lower control panel specified by the setting of extended menu item 118 are disabled.
5PROCESS CONTROL switch
This selects the method of control of the internal digital video processor.
REMOTE: Select this position to use an optional remote control unit for remote control of the internal digital video processor.
MENU: Select this position to use the setup menu to change the settings for the internal digital video processor.
LOCAL: Select this position to use the subsidiary control panel to change the settings for the internal digital video processor.
6
This switch is used to make selections relating to the time code and the internal time code generator.
(In this Operating Instructions, this switch may also be called simply as the INT/EXT switch or PRESET/ REGEN switch depending on the contents of the description in which the switch is referred to.)
| Selection of internal/external time code | |
Setting | Time code used | |
|
| |
INT | The time code produced by the internal time | |
| code generator | |
| By setting the switch to | |
| PRESET, you can select “PRESET” or “REGEN” | |
| for the internal time code generator (see the | |
| next table). | |
|
| |
EXT | The external time code selected as follows. | |
| • | When the TC SELECT switch is set to TC |
|
| The external time code input to the TIME |
|
| CODE IN connector |
| • | When the TC SELECT switch is set to VITC |
|
| The VITC time code included in the input |
|
| video signal |
| In this case, for the internal time code generator, | |
| “REGEN” is always selected (see the next | |
| table). | |
|
|
|
Selection relating to the internal time code generator
Setting | Operation of the internal time code generator |
|
|
PRESET | The initial value of the time code produced by |
| the internal time code generator can be preset |
| by a control panel operation or by remote control |
| from a device connected to the |
| |
|
|
REGEN | The internal time code reader is synchronized to |
| the playback time code read by the internal time |
| code reader. |
|
|
7FREE RUN/REC RUN switch
This switch selects the time code run mode of the internal time code generator.
FREE RUN: Regardless of the operating mode of this unit, the time code value advances continuously while the power is on.
REC RUN: The time code value advances only during recording. When this mode is selected, set the INT/EXT−PRESET/REGEN switch to INT−
PRESET.
8DF/NDF
This switch selects the mode of advancing the time code generator and time counter.
DF:
NDF:
Note
When the PRESET/REGEN switch is set to REGEN, since the time code generator is synchronized to the playback time code, this switch has no effect.
9VITC switch
To record the time code produced by the internal time code generator as a VITC, set this switch to ON. When this switch is set to OFF, internally generated time code is not recorded as VITC, but VITC present in the input video signal is recorded unchanged.
!º TC (time code) SELECT switch
This switch selects the time code, TC or VITC, shown in the time counter display.
Overview 1 Chapter
Chapter 1 Overview 27