Troubleshooting and Maintenance 8 Chapter
Troubleshooting
Alarm messages and associated directions
Alarm message on monitor screen | Direction | Alarm message in the | |
|
|
| diaplay section |
Cause |
| ||
|
| ||
|
|
|
|
A cleaning tape has been inserted. | The tape will automatically be ejected after cleaning | Cleaning Tp | |
|
| is completed. |
|
|
|
|
|
A | Use a standard signal. | VIN | |
input video. |
|
| |
|
|
| |
A | Use a standard signal. | REF | |
REF. VIDEO. |
|
| |
|
|
|
|
Abnormal settings selected in setup menu. | Correct the setup menu settings. Contact your | ILL. SETUP | |
|
| Sony dealer if this alarm message appears again |
|
|
| after making corrections. |
|
|
|
| |
Audio mixing mode cannot be changed | — | REC mode! | |
during recording. |
|
| |
|
|
|
|
Audio not editable on this tape. | Use a tape recorded in | 2CH/32kHz! | |
|
|
| |
|
|
|
|
|
|
| Fs 44.1kHz! |
|
| Use a tape having audio signals recorded in locked | UNLOCK mode |
|
| mode. |
|
|
|
| |
Audio REC mode selection different from | Select the same audio recording mode as that of | A mode err | |
audio on tape. | the tape. |
| |
|
|
| |
Audio REC (recording) mode cannot be | — | REC mode! | |
changed during recording. |
|
| |
|
|
| |
Cassette adaptor not usable. | Use a tape without cassette adaptor. | Adaptor! | |
|
|
| |
Counter mode is selected. | Use the COUNTER SEL button to light the TC or U- | CNT mode! | |
|
| BIT indicator in the display section. |
|
|
|
| |
Input selection cannot be changed in REC | — | REC mode! | |
(recording) mode. |
|
| |
|
|
| |
Input signal does not conform to DVCAM/DV | — | Unknown Sig | |
format. |
|
| |
|
|
| |
Input signal is 625/50. (For | — | 625/50 sig! (For DSR- | |
|
|
| 2000A) |
Input signal is 525/60. (For | — | 525/60 sig! (For DSR- | |
|
|
| 2000AP) |
Input video is not detected. | Check the INPUT VIDEO indication in the input | No INPUT! | |
|
| selection/audio mode display section and supply an |
|
|
| appropriate video signal. |
|
|
|
| |
Input video signal does not synchronize with | Use a common reference signal or connect the | ILL. REF! | |
REF. VIDEO signal. | recorder REF. VIDEO OUT connector to the player |
| |
|
| REF. VIDEO IN connector. |
|
| Note |
|
|
| When connecting the recorder REF. VIDEO OUT |
| |
| connector to the player REF. VIDEO IN connector, |
| |
| set extended menu item 308 to |
| |
|
|
| |
Key inhibit mode is selected. | Set the KEY INHIBIT switch on the subsidiary | KEY INHI. | |
| control panel to OFF. |
| |
|
|
|
|
Moisture has been detected. | Keep the power on and wait until this alarm | HUMID! | |
| message disappears. |
| |
|
|
|
|
No cassette in VTR. | Load a cassette. | No Cass.! | |
|
|
| |
Rec inhibit mode is selected. | Set the REC INHIBIT switch on the subsidiary | REC INHI.! | |
| control panel to OFF. |
| |
|
|
| |
Record inhibit plug on the cassette is set to | Set the REC/SAVE switch on the cassette to REC. | REC INHI.! | |
inhibit. |
|
|
|
138 | (Continued) |
Chapter 8 Maintenance and Troubleshooting |