Connections for Two-Unit Synchronous Playback

The following shows connections for synchronous playback using two DSR-2000A/2000AP units.

In the following, the controlling unit is referred to as the recorder and the controlled unit as the player.

For information about how to carry out two-unit synchronous playback, see the section “Synchronous Playback” on page 59.

1

REF.VIDEO IN

REF.VIDEO OUT

 

DSR-2000A/2000AP (recorder)

 

 

 

DSR-2000A/2000AP (player)

 

 

 

REMOTE-OUT

 

REMOTE-IN

2

1 75 coaxial cable (not supplied)

2 RCC-5G 9-pin remote control cable (not supplied)

DSR-2000A/2000AP (recorder) settings

Control

Setting

 

 

REMOTE button

Unlit

 

 

9PIN button

Lit

Setup menu item 004

ON (Synchronize.)

 

OFF (Do not

 

synchronize.)

 

 

Setup menu item 305

ACCUR (±0 frame)

(When synchronizing,

ROUGH (±1 frame)

synchronization accuracy)

 

 

 

REF. VIDEO IN 75

ON

termination switch

 

 

 

DSR-2000A/2000AP (player) settings

Control

Setting

 

 

REMOTE button

Lit

 

 

9PIN button

Lit

and Connections 7 Chapter

Settings

Chapter 7 Connections and Settings