Sony HD 3CCD operating instructions Symptom Cause Remedy

Models: HD 3CCD

1 80
Download 80 pages 7.24 Kb
Page 66
Image 66

Symptom

Cause

Remedy

The VISCA control is not available with

The computer is not correctly connected to

Make sure the connection between the

a computer connected to the camera.

the camera.

computer and camera is made correctly.

 

 

 

 

 

Check that the VISCA control setting (RS-

 

 

232C or RS-422) and the baud rate setting

 

 

(9600 bps or 38,400 bps) are properly made

 

 

with the BOTTOM switch on the bottom of

 

 

the camera (page 19) and the DIP switch on

 

 

the Remote Control Unit (page 23).

 

 

 

 

 

Try to connect the camera to the RM-BR300

 

 

Remote Control Unit to check that the camera

 

 

works properly.

 

 

 

The picture quality obtained from the

Depending on your computer or video capture

Consult with your computer manufacturer or

camera connected to a computer differs

board, you may not be able to obtain the

dealer for details.

from that from the camera connected to a

expected picture quality.

 

video monitor.

 

 

The camera cannot be operated at all.

Pull out the plug of the power cord from the AC outlet, then reinsert it into the AC outlet after a while.