Appendix

Appendix

List of Messages

The following messages may appear on the screen. Take the necessary measures shown below.

Indicators on the BRC-H700 camera

Indicator

Meaning/remedies

STANDBY lamp

The camera stopped moving due to an

flashes.

error in the pan/tilt mechanism. Reset

 

the pan/tilt position or turn off the power

 

of the camera and turn it on again.

 

 

The tally lamp

Turn off the power of the camera, and

flashes.

consult with your Sony dealer.

 

 

Messages for the BRC-H700 camera

Message

Meaning/remedies

Please restart system

You are prompted to restart the power of

 

the camera after you changed the setting

 

of “IMG-FLIP” in the SYSTEM menu.

 

Use the POWER switch on the supplied

 

Remote Commander or the POWER

 

button on the RM-BR300 Remote

 

Control Unit to turn the power off, then

 

on. The changed setting becomes

 

effective.

 

 

PRESET xx OK

When you store the camera settings into

(xx = 1 to 16)

the memory (POSITION 1-16), the

 

message will appear for 2 seconds.

 

 

One Push WB...OK

While the white balance is automatically

(NG)

adjusted, the message will appear. Wait

 

for a while. When the adjustment is

 

complete, it will disappear.

 

 

STOP

Turn off the power of the camera, and

(The message will

consult with your Sony dealer.

flash in FAN

 

MOTOR on PAGE5

 

in the STATUS

 

menu.)

 

 

 

CAUTION

Turn off the power of the camera, and

COOLING FAN 1

consult with your Sony dealer.

(2), (1, 2)

 

STOPPED!

 

 

 

Error messages for the BRU-H700 HD Optical Multiplex Unit

Message

Meaning/remedies

Communication error

The message will appear when the HD

Please check

Optical Multiplex Unit is turned on, if a

connection

problem occurs in the connection of the

 

Optical Fiber Cable between the camera

 

and the HD Optical Multiplex Unit.

 

Turn off the power of the camera and

 

the HD Optical Multiplex Unit, check

 

the connection of the Optical Fiber

 

Cable and turn the powers on again.

 

This message will also appear when the

 

power of the camera is not turned on.

 

Turn off the HD Optical Multiplex Unit,

 

turn on the camera, then turn on the HD

 

Optical Multiplex Unit again.

 

 

Option card error

The message will appear when an

Please check option

interface board that cannot be used with

card

the HD Optical Multiplex Unit is

 

inserted into the card slot. Turn off the

 

power of the HD Optical Multiplex Unit

 

and remove the board.

 

 

CAUTION

Turn off the power of the camera, and

COOLING FAN

consult with your Sony dealer.

STOPPED!

 

 

 