Firmware Package History

BlueScale2.6.0.6

This firmware release improves overall reliability of the nTier700.

Resolved Issues

Disconnecting and reconnecting the cables to the Ethernet ports on the nTier700 back panel no longer causes the system to hang.

Known Issues

Problem

Workaround

 

 

Update from BlueScale 2.2 or 2.3 to 2.6.0.6 fails

This update must be performed by Spectra Logic

unless specific procedures are carefully followed.

Technical Support personnel (see Contacting

 

Spectra Logic on page 4).

 

 

After disabling a NIC through the BlueScale web

Do not disable NICs.

interface, the operator panel no longer operates

 

correctly.

 

 

 

If you are updating the firmware for the root

Before you update the nTier700 firmware for the

expanders from a previous version, the firmware

root expanders, stop all I/O to the drives, then

update fails if there is I/O to the drives during the

stop BlueScale. The expander firmware is

update.

updated as part of the BlueScale 2.2 or 2.3 to

 

BlueScale 2.6.0.6 update procedure performed by

 

Spectra Logic Technical Support.

 

 

Occasionally, you may not be able to navigate to

1. Access the Windows desktop.

the BlueScale Network screen when the optional

2. Configure the IP addressing for the installed

10 GigE NIC is installed.

network interface cards through Windows.

 

(Start > Settings > Network Connections,

 

select the desired connection, and then select

 

Properties to configure the IP addressing.

 

 

Following a reboot of the nTier700, the BlueScale

Reboot the system again.

web interface shows the status for all system

 

components as unknown and Last Update as old.

 

 

 

BlueScale posts critical error messages about

Ignore critical messages concerning the missing

missing blades immediately following a system

blades IF they are posted immediately following

start or reboot.

a BlueScale restart (for example, a system reboot).

 

Mark the messages as Read and then continue to

 

monitor the messages for subsequent critical

 

alerts for the same components.

 

 

If you have a proxy server defined for Internet

Download the firmware update file to either a

Explorer you cannot use the Download From

USB drive or a firmware package server and

Spectra option to update the nTier700 BlueScale

update the firmware from there.

firmware.

 

 

 

June 2010

Spectra nTier700 Backup and Archive Appliance

17

Page 17
Image 17