Chapter 8—Maintaining the nTier700

4.If the firmware package includes updates to the firmware for the Adaptec RAID controller HBA, the blades, or the root expanders, a Confirmation Needed page similar to the one shown in Figure 23 displays.

Figure 23 Confirmation message to update the HBA.

Note: The BlueScale firmware prevents the Adaptec RAID controller

 

firmware and /or driver from being updated if a RAID is actively

 

performing any task (for example, a RAID volume is either

 

building or rebuilding).

 

In this case, a message displays to indicate that the RAID

 

controller firmware was not updated because the RAID was

 

actively performing another task. The only available option in

 

this case is Cancel. Wait until the RAID tasks are complete, then

 

begin the update process again.

 

 

Choose...

If...

 

 

Continue Install

Your nTier700 is prepared for the system to reboot. The progress page

 

redisplays and the update continues.

 

 

Cancel

Your nTier700 is in a state where a reboot would impact operations. Wait until

 

the nTier700 is in a state where it is ready for a reboot, then simply begin the

 

update process again.

 

Note: If the RAID is actively performing any task (for example, a RAID volume

 

is being built), the only option available is Cancel.

 

 

5.When the firmware update is finished the system reboots.

Note: If the firmware for the root expanders or blades was updated, the nTier700 will shutdown. Power on the system and wait for the Windows operating system to restart.

6.Reconnect to the BlueScale web interface.

June 2010

Spectra nTier700 Backup and Archive Appliance

59

Page 59
Image 59
Spectra Logic NTIER700 manual Choose Continue Install, Cancel