20 Netra 440 Server System Administration Guide August 2004
FIGURE 1-5 Patch Panel Connection Between a Terminal Server and a Netra 440 Server
If the pinouts for the serial management port do not correspond with the pinouts for
the RJ-45 ports on the terminal server, you need to make a crossover cable that takes
each pin on the Netra 440 server serial management port to the corresponding pin in
the terminal server’s serial port.
TABLE 1-3 shows the crossovers that the cable must perform.
TABLE 1-3 Pin Crossovers for Connecting to a Typical Terminal Server
Netra 440 Serial Port (RJ-45 Connector) Pin Terminal Server Serial Port Pin
Pin 1 (RTS) Pin 1 (CTS)
Pin 2 (DTR) Pin 2 (DSR)
Pin 3 (TXD) Pin 3 (RXD)
Pin 4 (Signal Ground) Pin 4 (Signal Ground)
Pin 5 (Signal Ground) Pin 5 (Signal Ground)
Pin 6 (RXD) Pin 6 (TXD)
Pin 7 (DSR /DCD) Pin 7 (DTR)
Pin 8 (CTS) Pin 8 (RTS)
Patch cable to serial management port
Patch panel
Terminal server
Straight-through cable
Netra 440
server