SyncServer S100

Figure 5-41:Time Information String Parameters

Comm parameters can be controlled by modifying the /etc/.ss_profile file.

Various operational parameters for the sysplex daemon can be controlled using parameters in the .ss_profile file. Use the serial connection or SSH to login to the S100 in order to change this file. Set the value of the SYSPLEX_PROGRAM environment variable by adding or removing the # comment character in the first column. For example:

#which sysplex program shall we run SYSPLEX_PROGRAM=sysplex #SYSPLEX_PROGRAM=sysplexoddp #SYSPLEX_PROGRAM=sysplexnof #SYSPLEX_PROGRAM=sysplexoddpnof SYSPLEX_OPTIONS=on

will run the standard (9600,8,n,1) version of the protocol while:

#which sysplex program shall we run #SYSPLEX_PROGRAM=sysplex SYSPLEX_PROGRAM=sysplexoddp #SYSPLEX_PROGRAM=sysplexnof #SYSPLEX_PROGRAM=sysplexoddpnof SYSPLEX_OPTIONS=on

88

S100 User Guide – Rev. D – June 2005

Page 96
Image 96
Symmetricom S100 manual 41Time Information String Parameters