Telos ZephyrExpress user manual Times, # for decimal numbers

Models: ZephyrExpress

1 186
Download 186 pages 4.48 Kb
Page 140
Image 140

In addition, Expert level includes these commands:

 

numbase

<dechexbinnone>

Set default number base to either decimal,

 

 

 

 

 

hexadecimal, binary or none. If none is

 

 

 

 

 

selected all numbers must be preceded by

 

 

 

 

 

explicit specifiers.

 

 

 

 

 

The default base can always be overridden

 

 

 

 

 

by explicit specifiers:

t

 

 

 

% for binary

 

 

 

$ for hex

 

 

 

# for decimal numbers.

 

NumbaseDEEP TECHisNOTE!provided for users who want to write their own control software. It

 

 

affects only the remote control function: the displays remain in decimal at all

 

 

times.

 

 

 

 

 

 

 

 

oscill

<onoff>

 

Switch on/off test tone oscillator on both

 

 

 

 

 

mic inputs.

 

 

 

 

 

 

parport

none

 

Display parallel contact closure status.

 

 

 

[<val0..valF>

Sets the four parallel contacts to match the

 

 

 

 

 

bit pattern and ignore incoming ancillary

 

 

 

 

 

data.

 

 

 

<norm>]

 

Restores normal operation.

 

 

 

example parport

val3

Sets contacts to off-on-on-on.

 

 

 

 

 

 

reset

[coldres]

 

Reset the system by restarting the code

 

 

 

 

 

without physical reset. cold will wipe out

 

 

 

 

 

all user-defined system parameters and

 

 

 

 

 

setups. res will maintain user settings.

 

 

 

 

 

We may ask you to enter some other

 

 

 

 

 

arguments during a support call.

 

 

 

 

 

 

rtcset

<date time>

 

Set date and/or time of RTC (real time

 

 

 

 

 

clock).

 

 

 

 

 

 

switch

 

 

Return information about internal and

 

 

 

 

 

backpanel switches.

 

 

 

 

 

 

SYSTEM FUNCTIONS

8-11

Page 140
Image 140
Telos ZephyrExpress user manual Times, # for decimal numbers