Toshiba RAV-SM560XT-E, RAV-SM800XT-E service manual Outdoor Unit RAV-SM800AT-E

Models: RAV-SM560XT-E RAV-SM800XT-E

1 88
Download 88 pages 43.27 Kb
Page 13
Image 13
4-3. Outdoor Unit (RAV-SM800AT-E)

4-3. Outdoor Unit (RAV-SM800AT-E)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T03

+

 

 

 

 

 

 

 

 

 

RED

 

CN09

 

BU

 

 

 

 

 

 

 

 

 

 

 

CT

 

 

 

 

 

 

 

 

 

 

 

EU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CM

WHI

 

CN10

 

 

BV

 

 

 

 

 

 

 

Compressor

 

 

 

EV

IGBT

THERMOSTAT

 

 

 

 

 

 

 

 

 

T04

 

 

 

 

 

 

BLK

 

CN11

 

CT

BW

module

FOR

 

 

 

 

 

 

 

 

 

 

 

 

 

EW

COMPRESSOR

 

CN604 2 2

 

TE

 

 

 

 

 

4

BX

 

ORN

2 2

CN500

 

1

1

 

 

POWER SUPPLY CIRCUIT

BY

 

 

 

 

 

 

 

 

 

BZ

 

ORN

1 1

 

CN605

2

2

 

 

 

(FOR P.C. BOARD)

 

 

 

 

 

 

GRN

TS

 

 

 

 

 

 

 

Q200

 

 

 

 

 

 

 

 

 

 

4-WAY VALVE COIL

 

 

1

1

 

 

F04

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUSE

 

 

 

 

3 3

3

 

 

3

3

 

 

 

 

3.15A

 

 

 

 

 

 

 

 

TD

 

 

 

 

 

 

 

 

 

 

CN700

CN600 2

 

 

 

 

 

 

 

 

P20

 

1 1

1

 

 

1

1

 

 

 

 

 

C13

3

 

P19

YEL

FAN MOTOR

 

 

CN601 2 2

 

TO

 

 

 

C12

 

P18

BLU

5 5

 

 

1

1

 

 

 

 

C11

 

 

P17

 

 

 

 

 

 

 

 

 

 

 

 

FM

4 4

 

Fan

 

 

 

 

 

 

 

C10

2

F02

 

 

3 3 CN300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUSE

G

 

 

2 2

 

circuit

 

 

BLU

 

 

 

 

 

 

15A

 

 

1 1

 

 

3 3

 

3 3

 

 

 

 

 

E

 

 

 

2

CN302

 

 

CN04

 

 

 

 

A

Converter

 

3 3

 

 

YEL

 

 

 

 

 

 

 

 

 

1 1

 

1 1

 

 

 

 

 

~

module

 

2 2 CN301

F300

 

 

 

 

POWER

 

 

 

 

 

 

 

 

 

 

 

 

 

~

 

 

1 1

 

FUSE

5

5

BLK

 

5 5

 

 

RELAY

 

 

 

 

 

 

T5A

WHI

 

 

 

 

 

 

+

DB01

 

6 6

 

CN800

4

4

BLU

 

4 4

CN06

 

RY01

 

P10

 

 

 

 

3

3

 

3 3

 

 

 

 

 

5 5

 

RED

 

 

 

 

 

 

ORN

 

 

 

2

2

 

2 2

P.C. BOARD

R05

 

 

 

PMV

4 4

 

 

1

1

PNK

 

1 1

 

P11

REACTOR

3 3 CN702

 

 

 

 

 

 

 

 

 

 

 

 

(MCC-1359)

R06

 

P13

2 2

 

 

2 2

 

 

2 2

 

 

2 2

 

 

 

 

 

CN04

 

 

 

 

 

 

1 1

 

 

1 1

 

ORN

 

CN05

 

 

 

P12

 

 

 

1 1

 

1 1

 

T02

 

REACTOR

 

 

 

 

 

 

BLK

 

 

 

 

CT

 

P09

2 2

 

 

 

 

 

5

5

 

5 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 1

 

 

 

PHOTO COUPLER

 

 

 

 

 

 

P08

 

 

 

4

4

WHI

 

4 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P15

 

 

 

 

 

 

3

3

 

3 3

 

 

 

 

 

BRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN01 2 2

RED

 

2 2

 

 

 

 

P14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1

 

1 1

CN13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SUB

 

2

F01

 

 

 

 

 

 

 

 

 

 

 

 

P.C. BOARD

 

FUSE

 

 

 

 

 

 

F01

VARISTOR

SURGE

 

 

(MCC-1398)

 

T3.15A

 

 

 

 

 

2

FUSE

 

 

 

 

 

 

 

 

 

25A

 

ABSORBER

 

 

 

 

CN02

1 2 3

 

 

 

REACTOR

 

CN01

CN02

 

CN03

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

WHI

 

BLK

 

 

 

 

 

1 2 3 GRY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHI

RED

 

 

 

 

 

1

1 2 3 L N

TERMINAL OF COMPRESSOR

 

 

 

TO

POWER

WHITE(S)

BLACK(C)

The sign in ( )

 

 

INDOOR SUPPLY

 

 

 

UNIT

220-240V

 

 

is displayed

 

 

 

~50Hz

 

 

in the terminal

 

 

 

 

 

RED(R)

cover

SIMPLE CHECK POINTS FOR DIAGNOSING FAULTS

Check

Diagnosis result

items

 

 

 

1

TERMINAL BLOCK

 

There is no supply voltage

Connecting cable check

(AC220 to 240V) between L - N , 1 - 2

 

 

There is no voltage (DC15 to 25V) 2 - 3

 

 

 

 

 

 

FUSE

 

2

25A fuse (F01) blown, 15A fuse (F02) blown

Converter module (DB01) and electrolytic

3.15A fuse (F04) blown,

capacitor (C10 to C13) check IGBT

T5A fuse (F300) blown (SUB P.C. board)

 

module (Q200) check, Fan motor check

 

T3.15A fuse (F01) blown (SUB P.C. board)

SUB P.C. board check

 

 

 

3

ELECTROLYTIC CAPACITOR VOLTAGE (C10, C11, C12, C13)

DC320V not available between

25A fuse (F01) check

+ terminal of electrolytic capacitor

 

P.C. board and coverter

 

 

 

 

module (DB01) check

 

 

 

 

 

INVERTER OUTPUT (CN09, CN10, CN11)

 

4

(Please confirm within six minutes after instructing in the drive.)

Voltage between each line of inverterside

IGBT module and

 

conector pins are not equal.

 

P.C. board check

 

 

 

 

Color Identification

BLK

: BLACK

WHI : WHITE

BLU

: BLUE

BRN : BROWN

RED

: RED

ORN : ORANGE

GRY

: GRAY

YEL : YELLOW

PNK

: PINK

PUR : PURPLE

GRN

: GREEN

 

– 11 –

Page 13
Image 13
Toshiba RAV-SM560XT-E, RAV-SM800XT-E service manual Outdoor Unit RAV-SM800AT-E