9-5-5. Console Installation
•Select the terminal of
C F
INSTALL
A B
REMOCON
<Install the indoor unit>
•Install the Installation plate 1 at the wall according to the Paper pattern.
•Hang the indoor unit on the hooks of the Installation plate 1.
•Fix the lower portion of the indoor unit with Mounting screws 4 (2 places).
Indoor unit
Hook
1Installation plate
Fig.
<Cutting a hole and mounting the Installation plate>
•When installing the rear piping, determine the pipe hole position, drill the pipe hole (∅80 mm) at a slight downward slant to the outdoor side.
4Mounting screw
•For mounting of the Installation plate 1, use the
Paper pattern, which is inside the package box cover.
|
| 1093 | 375 mm |
|
|
| 742 | or more |
|
|
|
|
| |
| 160 |
| 633 | 4 Mounting screw |
|
|
|
| |
390mm | ormore | 320 |
| Fig. |
60 | <Condition for installation> | |||
|
|
| 140 | • The unit must not decline more than 15 mm in either |
|
|
|
| |
|
| Floor | Rear piping hole ∅80 | axis. |
|
|
| ||
|
|
|
| |
|
|
|
| 15 mm |
Fig.
Anchor bolt
Projection
15 mm or less
5 mm dia. hole
4Mounting screw ∅4 x 25 s
Clip anchor (local parts)
Fig.
CAUTION
Failure to firmly install the unit may result in personal injury and property damage if the unit falls.
•In case of block, brick, concrete or similar type walls, make 5 mm dia. holes in the wall.
•Insert clip anchors for appropriate Mounting screws
4.
Fig.
<Piping and Drain Hose Installation>
•The piping direction can be the following 3 ways with the Drain hose.
•Each piping direction
should be connected with the Flexible pipe 5.
Rear piping
Side piping
Bottom piping
Fig.
•Cut or remove the determined direction slit or cover.
NOTE :
•Secure four corners and lower parts of the Installation plate 1 with 6 to 8 mounting screws to install it.
– 35 –
| Slit for upper |
Cover for | piping |
side piping | Cover for rear |
| |
| upper piping |
Fig.