9. INSTALLATION PROCEDURE

Remark per EMC Directive 89/336/EEC

To prevent flicker impressions during the start of the compressor (technical process) following installation conditions do apply.

1.The power connection for the air conditioner has to be done at the main power distribution. This distribution has to be of an impedance.

Normally the required impedance is reached at a 32A fusing point. Air conditioner fuse has to be 16A max.!

2.No other equipment should be connected to this power line.

3.For detailed installation acceptance, please contact your power supplier whether its restriction does apply for products like washing machines, air conditioners or electrical ovens.

4.For power details of the air conditioner, refer to the rating plate of the product.

9-1. Installation Diagram of Indoor and Outdoor Units

(Under Ceiling Installation)

or

more

200

mm

 

Pipe shield

 

 

 

re

 

 

 

o

 

 

 

m

 

 

r

 

 

o

 

 

 

m

 

 

 

m

 

 

0

 

0

 

 

2

 

 

 

70 m m or m ore

7Zeolite filter

9 Filter frame

8 Purifying filter

Air filter

(Console Installation)

Hook

1 Installation plate

4 Mounting screw

200m

or m m ore

200

mm

or

 

 

m

 

 

ore

re o m

or

m m

70

Before install the wireless remote controller

With the remote controller cover open, load the batteries supplied correctly, observing their polarity.

%Wireless remote controller

Cover

! Batteries

#Pan head wood screw

%Wireless remote controller

" Remote controller holder

Insulate the refrigerant pipes separately with insulation, not together.

Min 6 mm thick heat resisting polyethylene foam

– 27 –