No. Part name | Procedure | Remarks |
Š Fan guard | 1. Detachment | Discharge | |
| 1) Perform works of items 1 of • and „. | ||
| port cabinet | ||
| 2) Remove the air flow cabinet, and put it |
| |
|
| down so that the fan guard side directs | Bell mouth |
|
| downward. | |
|
|
|
|
|
| Perform work on a corrugated card- |
|
|
| board, cloth, etc. to prevent flaw to the | Remove |
|
| product. | |
|
| two screws | |
|
|
|
|
3)Take off screws fixing the bell mouth. (ST1Tf4 x 10L, 2 pcs.)
4) Remove the bell mouth. | Bell mouth |
5)Remove the hooking claws by pushing with minus screwdriver along with the arrow mark as shown in right figure.
2. | Attachment |
| Discharge |
| port cabinet | ||
1) | Insert claw of the fan guard in hole of the |
|
|
| discharge panel. Push the hooking claws | Minus screwdriver | Fan guard |
| (5 positions) with hands and fix the claws. | ||
|
|
|
After all the attachment works are completed, check that all the hooking claws are fixed to the specified posi- tions.
2)Mount the bell mouth by hooking three claws at upper side of the bell mouth in the slits on the discharge cabinet.
3) After attachment, fix the bell mouth with | Hooking claw |
screws. (ST1Tf4 x 10L, 2 pcs.) |
|
| Discharge port cabinet |
Slit (3 positions)
Bell mouth
Claw (3 positions)
– 79 –