No. | Part name |
| Procedure | Remarks |
|
|
|
| |
† Fan motor | 1) | Perform works of items 1) to 5), 7) of • |
| |
|
| 2) | Remove the flange nut fixing the fan motor |
|
|
|
| and the propeller fan. | Flange |
|
|
| • Loosen the flange nut by turning clock- | nut |
|
|
|
| |
|
|
| wise. (To tighten the flange nut, turn it |
|
|
|
| counterclockwise.) |
|
3)Remove the propeller fan.
4)Remove the lead wire from the hook fixing the fan motor lead wires on the motor base. (Three positions)
5) Disconnect the connector for fan motor | Loosen by turning |
clockwise | |
from the inverter. |
|
6)Take off the fixing screws (4 pcs.) while holding by hands so that the fan motor does not fall.
NOTE :
Tighten the flange nut with torque 9.8Nm (100kgf/cm).
Propeller fan
Fan motor
Motor base | Fixing claws for |
| fan motor lead |
| wires (3 positions) |
– 76 –