![‡ Compressor](/images/new-backgrounds/34996/34996143x1.webp)
No. Part name |
| Procedure | Remarks | |
|
|
|
|
|
‡ Compressor | 1) | Perform works of items 1 of • and |
|
|
|
| ‚, ƒ, „, …. | Partition plate | |
| 2) | Discharge refrigerant gas. |
|
|
| 3) | Remove the partition plate. |
|
|
|
| (ST1T Ø4 x 10L, 2 pcs.) |
|
|
|
|
|
|
4)Remove the
5)Remove the terminal covers of the compressor, and disconnect lead wires of the compressor and the compressor thermo assembly from the terminal.
6)Remove pipes connected to the compressor with a burner.
| Compressor |
| lead |
CAUTION |
|
Pay attention to that flame does not | Case thermo |
involve | |
so, a malfunction may be caused.) |
|
7)Take off the fixing screws of the bottom plate and heat exchanger.
| (ST1T Ø4 x 10L, 2 pcs.) |
| Heat exchanger |
8) | Take off the fixing screws of the valve | Remove |
|
| clamping plate to the bottom plate. |
| |
9) | Pull upward he refrigerating cycle. | (Discharge pipe) |
|
|
| ||
10) Take off nut fixing the compressor | Remove |
| |
| to the bottom place. | Screw | |
|
| (Suction pipe) |
|
| CAUTION |
| Valve |
|
| support board | |
When reconnecting the lead wires to |
| Screws (2 pcs.) | |
the compressor terminals after |
| Compressor bolt (3 pcs.) | |
replacement of the compressor, be |
| ||
|
| ||
sure to caulk the Faston terminal |
|
| |
without loosening. |
|
|
ˆ Reactor | 1) | Perform works of item 1 of • and ƒ. |
|
|
|
|
|
| 2) | First take off two screws (ST1T Ø4 x |
|
| Partition | Reactor | |
|
| 10L) of the reactor fixed to the reactor | Reactor | plate | |||
|
|
|
| support board | |||
|
|
|
|
|
| ||
|
| support. |
|
|
|
|
|
| 3) | Remove the reactor support from the |
|
|
|
|
|
|
|
|
|
|
| ||
|
| partition plate. |
|
|
|
|
|
|
| (ST1T Ø4 x 10L, 4 pcs.) |
|
|
|
|
|
| 4) | Take off two screws (ST1T Ø4 x 10L) |
|
|
|
|
|
|
| directly attached to the partition plate. |
|
|
|
|
|
|
|
|
|
|
|
|
– 70 –