13-4-1. Clearing method of self diagnosis result

13-4-1. Clearing method of self diagnosis result

In the error count state of screen, press “CHANNEL DOWN” button on TV set pressing “DISPLAY” button on remote unit.

CAUTION:

All ways keep the following caution, in the state of service mode screen.

Do not press “CHANNEL UP” button. This will cause initialization of memory IC. (Replacement of memory IC is required.)

Do not initialize self diagnosis result. This will change user adjusting contents to factory setting value. (Adjust- ment is required.)

13-4-2. Method utilizing inner signal

(VIDEO INPUT 1 terminal should be open.)

(1)With service mode screen, press VIDEO button on re- mote unit. If inner video signal can be received, QV01 and after are normal.

(2)With service mode screen, press “8” button on remote unit. If sound of 1 kHz can be heard, QV01 and after are normal.

*By utilizing signal of VIDEO input terminal, each circuit can be checked. (Composite video signal, audio signal)

White

Yellow

Cyan

Green

Magenta

Red

Blue

(COLOR BAR SIGNAL)

Color elements are positioned in sequence of

high brightness.