7. X-RAY PROTECTION CIRCUIT

7-1. Outline

In case picture tube using high voltage, when high voltage rises abnormally due to components failure and circuit mal- function, there is possible danger that X-RAY leakage in- creases to affect human body. To prevent it, X-RAY protec- tion circuit is equipped.

7-2. Operation

Figure 9-23 shows the circuit diagram. Supposing high volt- age rises abnormally due to some reason, pulse at pin 9 of T461 also rises, and detection voltage ED rectified by D471 and C471 in X-RAY protection circuit rises. When ED rises, emitter voltage of Q464 divided by R459 and R462 becomes higher than [zener voltage (6.2V) of D458 + Q464 VBE ]. This causes Q464 turns on to supply base current to Q463.

Then Q463 turns on. By this Tr6 and Tr6 turn on to make ON/OFF pulse at pin 7of QA01 in low level, Q846 and Q845 turns off, then relay SR81 turns off. Tr6 and Tr7 are in thy- ristor-connection, and 5V of power holds protection opera- tion until main power switch is turned off. During circuit operation, power LED near main power switch blinks turn on and off in red.

Caution:

• To restart TV set, repair failure first.

5V

Z801

15

 

 

 

R9

 

 

 

R10

 

12V

 

Tr7

 

 

 

 

 

Q463

 

R19

C894

Q464

R459

RELAY

Q846

Tr6

 

14

 

 

 

 

 

 

 

 

SR80

16

R12

C1

 

 

R462

 

 

D459

C458

 

 

 

 

 

 

 

 

Tr5

 

R879

R468

 

 

 

 

 

 

 

 

 

R458

Q845

R11

R467

D458

 

 

C459

17

ED

R472 T461

9

D471 C471

Fig. 9-23 X-RAY protection circuit