2-70 Installation
DSU DIM Installation
Other Reporting
Differences
Other differences in control terminal output are:
Detailed Port Statistics— show DSU input and output signaling as well as
note the installed DSU DIM
Detailed Node Statistics— show DSU DIM installation
Example of
Diagnostics Menu
Figure 2-24 shows the Diagnostics menu within the CTP in the control terminal. You
use this menu to access the loopback options described in the next section.
Figure 2-24. Diagnostics Menu
Control Terminal
Loopback Options
The following table describes the control terminal loopback options.
Node: nodename Address (blank)Date: -------- Time: ------
Menu: Diagnostics Path: (Main.12)
1. Local Loopback
2. V.54 Loopback 2
3. V.54 Loopback 3
4. Fatal Error Reports
5. Logged Alarms«
6. Startup Diagnostics
7. DSU Internal Loopback
8. DSU Internal and External Loopback
9. Start Delay Measurement
10. Stop Delay Measurement
11. Display Delay Summary
12. IP Ping
#Enter Selection:
DSU Internal Loopback This loopback mode does not affect the external
interface but it does loop the local transmit data back to
the receive data within the EIM. This test is useful for
verifying that the EIM is connected and is working
properly from a digital integrity perspective.
DSU Internal and
External loopback
This loopback mode performs the internal loopback
mentioned above along with looping the external
transmit to the external receive to allow manual testing
of the remote interface.