204 Chapter
LIBRARY LIST
Initial Settings
Preference | Options | Initial Setting |
|
|
|
EQ AUTO SCREEN | ON/OFF | ON |
|
|
|
PANPOT AUTO SCREEN | ON/OFF | ON |
|
|
|
STORE CONFIRMATION | ON/OFF | ON |
|
|
|
RECALL CONFIRMATION | ON/OFF | OFF |
|
|
|
DIGITAL IN SYNC CAUTION | ON/OFF | ON |
|
|
|
“SELECTED CH” MESSAGE | ON/OFF | ON |
|
|
|
DELAY UNITS | msec, meter, sample | msec |
|
|
|
INC/DEC SCENE RECALL | ON/OFF | OFF |
|
|
|
LIBRARY LIST ORDER | UP/DOWN | UP |
|
|
|
Initializing the 01V
The Initialization function can be used to reset the 01V to its factory settings, clear all programs in the EQ, effects, and dynamics libraries, empty all scene memories, and reset the MIDI Program Change to scene memory, and Control Change to parameter assignment tables.
Note: If you want to reset just the mix settings and retain the programs and scene mem- ories, recall scene memory 00 instead. See “Scene Memory 00” on page 185 for more infor- mation.
1.Turn off the 01V.
2.While holding down the [MEMORY] button, turn on the 01V.
<<INITIALIZE MEMORY?>> appears on the display.
3.Release the [MEMORY] button.
4.Press the [+1/DEC] to initialize the 01V, or the
If you choose to initialize the 01V, mix settings are reset to their factory settings, all pro- grams in the EQ, effects, and dynamics libraries are cleared, the scene memories are emptied, and the faders are calibrated.
Calibrating the Faders
If the 01V is not used for a long time, it’s moved to a new location, or fader movements have been obstructed, the faders may need calibrating. The calibration process calculates the torque required by each fader motor to drive its fader accurately and smoothly.
1.Turn off the 01V.
2.While holding down the [ENTER] button, turn on the 01V.
3.Release the [ENTER] button.
The fader calibration process starts. When the faders return to their original positions, calibration is complete. Do not attempt to use the 01V before calibration is completed.