204 Chapter 15—Other Functions

LIBRARY LIST ORDER—When this option is set to UP, EQ, effects, dynamics, and scene memory lists appear with the lowest program/scene at the bottom and the highest at the top. When set to DOWN, they appear with the lowest at the top, highest at the bottom.

Initial Settings

Preference

Options

Initial Setting

 

 

 

EQ AUTO SCREEN

ON/OFF

ON

 

 

 

PANPOT AUTO SCREEN

ON/OFF

ON

 

 

 

STORE CONFIRMATION

ON/OFF

ON

 

 

 

RECALL CONFIRMATION

ON/OFF

OFF

 

 

 

DIGITAL IN SYNC CAUTION

ON/OFF

ON

 

 

 

“SELECTED CH” MESSAGE

ON/OFF

ON

 

 

 

DELAY UNITS

msec, meter, sample

msec

 

 

 

INC/DEC SCENE RECALL

ON/OFF

OFF

 

 

 

LIBRARY LIST ORDER

UP/DOWN

UP

 

 

 

Initializing the 01V

The Initialization function can be used to reset the 01V to its factory settings, clear all programs in the EQ, effects, and dynamics libraries, empty all scene memories, and reset the MIDI Program Change to scene memory, and Control Change to parameter assignment tables.

Note: If you want to reset just the mix settings and retain the programs and scene mem- ories, recall scene memory 00 instead. See “Scene Memory 00” on page 185 for more infor- mation.

1.Turn off the 01V.

2.While holding down the [MEMORY] button, turn on the 01V.

<<INITIALIZE MEMORY?>> appears on the display.

3.Release the [MEMORY] button.

4.Press the [+1/DEC] to initialize the 01V, or the [–1/INC] to cancel.

If you choose to initialize the 01V, mix settings are reset to their factory settings, all pro- grams in the EQ, effects, and dynamics libraries are cleared, the scene memories are emptied, and the faders are calibrated.

Calibrating the Faders

If the 01V is not used for a long time, it’s moved to a new location, or fader movements have been obstructed, the faders may need calibrating. The calibration process calculates the torque required by each fader motor to drive its fader accurately and smoothly.

1.Turn off the 01V.

2.While holding down the [ENTER] button, turn on the 01V.

3.Release the [ENTER] button.

The fader calibration process starts. When the faders return to their original positions, calibration is complete. Do not attempt to use the 01V before calibration is completed.

01V—Owner’s Manual