MIDI Data Format 285
PARAMETER CHANGE(type 0x05:remote meter)
When the following request is received to enable transmission, the specified parameter data will be transmitted at 30 msec intervals for five seconds. If you want meter data to be transmitted continuously, you must continue transmitting requests less than five seconds apart.
Reception
When [Parameter Change RX] is ON and the [Rx CH] matches the Device Channel that is included in the SUB STATUS, this message is received.
When [LOCAL OFF] is ON, the incoming meter data will be dis- played. In other cases it will be ignored.
Transmission
When transmission is enabled by a request, this will be transmitted every 30msec on the [Rx CH] channel, for five seconds. Transmission will be disabled when the power is turned on, and when PORT settings have been modified.
STATUS | 11110000 | F0 | System Exclusive Message |
ID No. | 01000011 | 43 | Manufacturer's ID No.(YAMAHA) |
SUB STATUS | 0001nnnn 1n | ||
GROUOP ID | 00111110 | 3e | MODEL ID |
MODEL ID | 00000100 | 04 | Device code (01V) |
PARAM TYPE | 00000101 | 05 | remote meter |
DATA | 0sgttttt tt | meter no.(s:special bit, g:gr bit) | |
| 0mmmmmmm mm0 |
| |
| 0mmmmmmm mm1 |
| |
| : | : |
|
EOX | 11110111 | F7 | End Of Exclusive |
In the Meter no., bit 6 is the special bit, and bit 5 is the gr bit. When the Gr bit is on, the single byte gr will be added uniformly to the end of the data string.
When the Special bit is on, the two bytes stLED L/R will be added uniformly to the end of the data string.
When both are on, gr comes first, and stLED L/R come later.
PARAMETER VALUE REQUEST(type 0x05:remote meter)
This message is used to obtain meter data from the 01V. It is used in LOCAL OFF MODE to display the meter of the remote device, or to display the meter on the screen of a personal computer, etc.
In order to obtain meter data, the meter whose data is required must be displayed in the LCD of the remote device. This means that before transmitting this request, you must first transmit the
Reception
When [Parameter Change RX] is ON and the [Rx CH] matches the Device Channel included in SUB STATUS, this message will be received.
When this message is received, Parameter Change (remote meter) messages will begin to be transmitted on the [Rx CH] channel.
Transmission
When [LOCAL OFF] is ON, transmit a meter data request for the currently displayed meter on the [Tx CH]. For each request, meter data will be transmitted for five seconds. If you want meter data continuously for longer than this, you will need to transmit requests at intervals of five seconds or less. When the 01V is in LOCAL OFF MODE, transmit requests at approximately
STATUS | 11110000 | F0 | System Exclusive Message |
ID No. | 01000011 | 43 | Manufacturer's ID No.(YAMAHA) |
SUB STATUS | 0011nnnn 3n | ||
GROUOP ID | 00111110 | 3e | MODEL ID |
MODEL ID | 00000100 | 04 | Device code (01V) |
PARAM TYPE | 00000101 | 05 | remote meter |
DATA | 0sgttttt tt | meter no.(s:special bit, g:gr bit) | |
EOX | 11110111 | F7 | End Of Exclusive |
Table of signal levels and codes
Level code Level code Level code
0x1F | 0x57 | 0x72 | |||
0x24 | 0x5A | 0x73 | |||
0x29 | 0x5F | 0x75 | |||
0x2F | 0x62 | 0x77 | |||
0x33 | 0x67 | 0x78 | |||
0x3A | 0x69 | 0x79 | |||
0x3F | 0x6A | 0x7A | |||
0x41 | 0x6B | 0x7B | |||
0x47 | 0x6D | 0x7D | |||
0x4A | 0x6F | 0dB | 0x7E | ||
0x4F | 0x70 | CLIP | 0x7F | ||
0x52 | 0x71 |
|
|
5.SYSTEM EXCLUSIVE MESSAGE (Bulk Dump) &
REQUEST
These messages input and output the contents of various types of internal memory.
The unique header identifies whether or not the data is for the 01V. The CHECK SUM is calculated by adding the data following the BYTE COUNT(LOW) until the data preceding the CHECK SUM, then inverting the bits (2's complement), and setting bit 7 to 0. CHECK SUM = (
Reception
This is received if [Bulk RX] is ON and the [Rx CH] matches the Device Channel that is included in SUB STATUS.
When a BULK DUMP is received, it will immediately be written into the specified memory.
When a BULK DUMP REQUEST is received, a bulk dump will be transmitted immediately.
Transmission
In the
In response to a Bulk Dump Request, a Bulk Dump Message is transmitted on the [Rx CH] channel.
data name rx/tx function
'M' | rx/tx | Scene Memory & Request |
'S' | rx/tx | Setup Memory & Request |
'I' | rx/tx | Remote(Internal Parameter) Memory & Request |
'L' | rx/tx | Remote(MMC) Memory & Request |
'U' | rx/tx | Remote(User Define) Memory & Request |
'C' | rx/tx | Control Change Assign Table & Request |
'P' | rx/tx | Program Change Assign Table & Request |
'Q' | rx/tx | Equalizer Library & Request |
'Y' | rx/tx | Dynamics Library & Request |
'E' | rx/tx | Effect Library & Request |