MIDI Setup 225

versa. When using the TO HOST port, PORT should be set to match the type of computer connected to the 01V, as follows.

Setting

Computer Platform

Port

Transmission Speed

 

 

 

 

MIDI

Standard MIDI

MIDI IN, OUT, THRU

31.25 kbps

 

 

 

 

PC1

NEC PC9800 Series

TO HOST

31.25 kbps

 

 

 

 

PC2

IBM PC compatible

TO HOST

38.4 kbps

 

 

 

 

Mac

Macintosh (clock: 1MHz)

TO HOST

31.25 kbps

 

 

 

 

Tx CH—This parameter determines which MIDI Channel the 01V uses to transmit MIDI messages, and can be set from 1 through 16. The device receiving MIDI messages from the 01V should be set to the same MIDI Channel. When the 01V transmits MIDI data in response to a request, that data is transmitted on the same MIDI Channel that the request was received on.

Rx CH—This parameter determines which MIDI Channel the 01V uses to receive MIDI messages, and can be set from 1 through 16. The device transmitting MIDI messages to the 01V should be set to the same MIDI Channel.When PROGRAM CHANGE OMNI or CONTROL CHANGE OMNI is turned on, program change and Control Change messages can be received regardless of this setting.

PROGRAM CHANGE—Program Change messages are used to recall mix scenes. See “Program Change Scene Recall” on page 227 for more information. The four ON/OFF switches in this group are as follows.

Tx determines whether the 01V transmits Program Change messages when a mix scene is recalled. Rx determines whether the 01V recalls mix scenes when Program Change messages are received. OMNI determines whether the 01V receives Program Change messages on all 16 MIDI Channels (ON) or just the Rx channel (OFF).

ECHO determines whether received Program Change messages are echoed through to the MIDI OUT port. When ECHO is on, the 01V receives Program Change messages and echoes them through to the MIDI OUT port regardless of the MIDI Channel set- tings.

CONTROL CHANGE—Control Change messages are used to control 01V parameters in real time. See “Control Change Parameter Control” on page 229 for more informa- tion. The four ON/OFF switches in this group are as follows.

Tx determines whether the 01V transmits Control Change messages when mix parameters are adjusted. Rx determines whether the 01V adjusts mix parameters when Control Change messages are received. OMNI determines whether the 01V receives Control Change messages on all 16 MIDI Channels (ON) or just the Rx channel (OFF).

ECHO determines whether received Control Change messages are echoed through to the MIDI OUT port. When ECHO is on, the 01V receives Control Change messages and echoes them through to the MIDI OUT port regardless of the MIDI Channel set- tings.

PARAM. CHANGE—Parameter Change System Exclusive messages are used to control 01V parameters in real time. See“System Exclusive Parameter Control”on page 231 for more information. The three ON/OFF switches in this group are as follows.

Tx determines whether the 01V transmits Parameter Change System Exclusive messages when mix parameters are adjusted. Rx determines whether or not the 01V adjusts mix parameters when Parameter Change System Exclusive messages are received. When Rx is turned on, the 01V transmits Parameter Change System Exclusive messages in response to requests even if Tx is turned off.

01V—Owner’s Manual