Program Change Scene Recall 227
Program Change Scene Recall
When a MIDI Program Change message is received, a mix scene is recalled in accordance with the scene memory to Program Change assignment table. Likewise, when a mix scene is recalled, the 01V transmits a Program Change message that can be used to recall a mix scene on another 01V or recorded to a MIDI sequencer for automated scene recall. See “Recalling Mix Scenes Using MIDI Program Change Messages” on page 188.
Initially, scene memories 1 through 99 are assigned sequentially to Program Changes 1 through 99 as listed in the “Scene Memory to Program Change Table” on page 273, although these assignments can be edited on MIDI page 2. These assignments are used for both transmission and reception, so if Program Change #10 is assigned to scene memory 20, the 01V recalls scene memory 20 when Program Change #10 is received, and transmits Program Change #10 when scene memory 20 is recalled.
In order for the 01V to receive and transmit MIDI Program Change messages, the Program Change Rx and Tx switches on MIDI page 1 must be turned on. See“MIDI Setup” on page 224 for more information.
1. Use the [MIDI] button to locate MIDI page 2, as shown below.
2.Use the cursor buttons to select the PGM CHG. column, and then use the PARAMETER wheel or
3.Use the right cursor button to select the NO. TITLE column, and then use the PARAMETER wheel or
A scene memory to Program Change assignment table is provided on page 273. To reset the assignments to their ini- tial settings, use the cursor buttons to select the INITIAL- IZE switch, and then press the [ENTER] button. The dialog box shown here appears. Click OK to initialize.
The current scene memory to Program Change assignment table can be stored to an external MIDI device, such as a MIDI data filer, using MIDI Bulk Dump. See “Bulk Dump” on page 232 for more information.
If a scene memory is assigned to two or more Program Changes, the lowest Program Change is transmitted when that scene memory is recalled.
If a scene memory that is not assigned to a Program Change is recalled, a System Exclu- sive Parameter Change Scene Recall message is transmitted. See “System Exclusive Parameter Control” on page 231 for more information.