256 | Troubleshooting |
| |
|
|
| |
| Symptom | Advice | |
|
|
| |
Fader movements are inconsistent. | Try calibrating the faders. See “Calibrating the Faders” on page 204 | ||
|
| ||
|
|
| |
|
| This warning message appears if digital signals from the Digital Stereo | |
DIGITAL IN Sync Error message | Coaxial In or Option I/O inputs are not wordclock synchronized with | ||
the 01V. Make sure that all digital equipment is wordclock synchro- | |||
appears. |
| ||
| nized to a common wordclock source. See “Setting the Wordclock” | ||
|
| ||
|
| ||
|
|
| |
UNLOCK appears in the Fs window | Make sure the external wordclock source is turned on and that the | ||
cable carrying the wordclock signal has not been disconnected. See | |||
of SETUP page 1. | |||
|
| ||
|
|
| |
Cannot transmit or receive MIDI | On MIDI page 1, check the following settings: PORT, Tx CH, Rx CH, | ||
and the Tx and Rx switches for Program Change, Control Change, | |||
messages. | |||
|
| ||
|
|
| |
|
| Make sure that the 01V is configured to receive Program Change mes- | |
|
| sages and that the MIDI Channels of the 01V and transmitting device | |
|
| ||
|
|
| |
MIDI Program Change messages | Perhaps the Program Change being transmitted is not assigned to an | ||
01V scene memory? Check the mix scene to Program Change assign- | |||
don’t recall mix scenes. | |||
ment table. See “Program Change Scene Recall” on page 227 for | |||
|
| ||
|
| ||
|
|
| |
|
| If the scene memory assigned to the received Program Change con- | |
|
| tains no data, it cannot be recalled. | |
|
|
| |
|
| Make sure that the 01V is configured to receive Control Change mes- | |
|
| sages and that the MIDI Channels of the 01V and transmitting device | |
MIDI Control Change messages | |||
| |||
Perhaps the Control Change being transmitted is not assigned to an | |||
don’t control mix parameters. | |||
|
| 01V parameter? Check the parameter to Control Change assignment | |
|
| table. See “Control Change Parameter Control” on page 229 for more | |
|
| ||
|
| ||
Cannot receive MIDI Bulk Dump | Make sure that the BULK Rx switch on MIDI page 1 is turned on. See | ||
data. |
| ||
|
|
| |
Controls have no effect on the 01V. | Perhaps the Local Control function on MIDI page 5 is turned off? See | ||
|
| ||
|
|
| |
MMC commands have no effect. | Make sure the device number matches that of the | ||
recorder. See “MIDI Machine Control” on page 236 for more informa- | |||
|
| ||
|
|
|