236 Chapter
MIDI Machine Control
Using MIDI Machine Control (MMC) commands, an
1. Use the [REMOTE] button to locate REMOTE page 2, as shown below.
While this page is displayed, controls other than [ON] buttons 1 through 6 and [SEL] buttons 1 through 6 are disabled.
2.Use the cursor buttons to select the DEVICE No. parameter, and the PARAMETER wheel or
The device number, which can be set from 1 through 127 or ALL, should be set to match that of the recorder you want to control. When set to ALL, all
3.Use [ON] buttons 1 through 6 to transmit the following transport com- mands to a recorder.
On Button | Function | MMC Command Value |
|
|
|
1 | Rewind | 05 |
|
|
|
2 | Fast Forward | 04 |
|
|
|
3 | Stop | 01 |
|
|
|
4 | Play | 02 |
|
|
|
5 | Pause | 09 |
|
|
|
6 | Record | 06 |
|
|
|
4.Use the cursor buttons and PARAMETER wheel or
5.Use [SEL] buttons 1 through 6 to transmit the locate commands to the recorder.
Locate points can be stored using MIDI Bulk Dump. See “Bulk Dump” on page 232 for more information.