56
Programming
System Related Commands
Status reporting commands
See also Status Reporting on page 69.
Note • All status commands are immediate, that is they pass the print queue and are answered directly.
ESC ENQ 1 |
| Status Enquiry |
1B 05 01 | hex | |
27 5 1 | decimal |
|
A status enquiry results in response ACK (6) if all sensors are clear, but NAK (15) + code if one or more sensors report some condition.
| Table 8 • Status Codes | ||
|
|
|
|
Status Code | Meaning |
| |
ACK | OK (printer is operable) | ||
NAK 1 | Paper left in presenter module. Attempt to clear the paper path failed. |
| |
NAK 2 | Cutter jammed |
| |
NAK 3 | Out of paper |
| |
NAK 4 | Printhead lifted |
| |
NAK 5 |
| ||
| printed. Paper might be wound around the platen or, in some way, has been | ||
| forced above the presenter module. | ||
NAK 6 | Temperature error. The printhead temperature has exceeded the 60 °C |
| |
| maximum limit. | ||
NAK 7 | Presenter not running (no feedback from code wheel) |
| |
NAK 0A | Black mark not found |
| |
NAK 0B | Black mark calibration error |
| |
NAK 0C | Index error |
| |
NAK 0D | Checksum error |
| |
NAK 0E | Wrong firmware type or target for firmware loading |
| |
NAK 0F | Firmware cannot start because no firmware is loaded or firmware |
| |
| checksum is wrong. | ||
NAK 10 | Waste bin timed out. If the customer doesn’t take the paper and the printer |
| |
| clears the presenter due to a timeout, the pending error bit is set and status | ||
| code NAK 16 is reported. | ||
NAK FF | Undefined error |
| |
Note • Errors 2, 5, and FF are terminal faults that require you to reset the printer before it will be operable again. The printer automatically recovers from the other conditions as soon as the cause is corrected.
A status enquiry command can only return one status code at a time. If there are two or more simultaneous conditions, each condition should be cleared and the status enquiry repeated in order to get a complete report of all status codes.
| TTP 8000 Technical Manual | 10/19/2009 |