86

Default Parameter Settings

Fixed Document Mode

53

0

Default

Lock Parameters

0

Min

 

1

Max

 

You can lock the parameters so that they cannot be changed by the ESC & P command.

 

 

 

<ESC>&P<53><0>

 

Unlocked

 

 

 

<ESC>&P<53><1>

 

Locked

 

255

Default

 

 

 

55

 

PSU Recovery

0

Min

 

 

255

Max

 

 

 

Adds a delay between the burning of blocks in the printhead. This delay helps possible for the power supply to recover from the heavy load of heating pixels. If you have a somewhat weak power supply, print quality can be enhanced by increasing this value. A high value slows the printout down slightly.

Recommended settings: 0 for 300 W (12.5 A) PSU, 255 for 150 W (6.5 A PSU)

P1003638-003

TTP 8000 Technical Manual

10/19/2009

Page 86
Image 86