Znyx Networks bh5700 manual Sensor Reading Example, Standard Ipmi Command GetSensorReading

Models: bh5700

1 359
Download 359 pages 3.51 Kb
Page 350
Image 350

Sensor Reading Example

This is an example of how to structure a command and response to determine a sensor value. In this example, a GetSensorReading command is sent from BMC (address 20h in this example), to the switch in slot 2 (geographical address is B2h) to read the temperature sensor, which is assigned to sensor number 60h.

Standard IPMI Command: GetSensorReading

Byte

Data Field

Description

1

rsAddr

B2h

 

 

 

2

netFn/Lun

10h

 

 

 

3

check1

3Eh

 

 

 

4

rqAddr

20h

 

 

 

5

seq no

06 (random pick)

 

 

 

6

command

2Dh

 

 

 

7

sensor number

60h

 

 

 

8

checksum2

4Dh

 

 

 

Table C.3: GetSensorReading

Ethernet Switch Blade User's Guide

release 3.2.2j

page 350

Page 350
Image 350
Znyx Networks bh5700 manual Sensor Reading Example, Standard Ipmi Command GetSensorReading, Table C.3 GetSensorReading