If the “Used” and “Free” memory statistics do not add up to the Total memory, the software environment may have a memory leak caused by a software error. Reboot the switch.

If the problem persists after a reboot. Run the top command to list the memory utilization of all current processes.

sh-2.04# top

The top command can help you isolate software related memory problems to specific processes.

Example output:

Testing the Control Processor

The Base Interface and Fabric Interface control processors are critical components in the operation of the Ethernet Switch Blade. The control processors host the OpenArchitect operating system and manage the switch fabric devices.