M States

M5 Deactivation request (e.g. hot swap ejector opened)

M6 Deactivation granted by ShMC

M7 Unexpected loss of communication between FRU and ShMC

Table C.1.: IPMI M States

Peripheral Management Controller Functional Support

The following IPMI commands are implemented in version 1.00:

 

 

PMC Controller Support

 

 

 

 

 

 

 

Command

 

Code

Sensor #

Status

Notes

 

 

 

 

 

 

GetDevID

 

0x01

 

Mandatory

 

 

 

 

 

 

 

BroadcastGetDeviceID

 

0x01

 

Mandatory

 

 

 

 

 

 

 

ColdReset

 

0x02

 

Optional

 

 

 

 

 

 

 

GetSelfTestResult

 

0x04

 

Mandatory

 

 

 

 

 

 

 

GetSensorReading

 

0x2D

 

Mandatory

 

 

 

 

 

 

 

TempSensor

 

 

60

 

Returned in Celsius

 

 

 

 

 

 

A2D_0

 

 

41

 

Full 8-bit value (255)

 

 

 

 

 

represents 3.3 Volts;

A2D_1

 

 

42

 

 

 

 

scale returned value

 

 

 

 

 

A2D_2

 

 

43

 

 

 

 

accordingly

A2D_3

 

 

 

Not used

 

 

 

 

 

 

 

A2D_4

 

 

45

 

 

 

 

 

 

 

 

A2D_5

 

 

 

Not used

 

 

 

 

 

 

 

SetSlotPower

 

0x12

 

Vendor

 

 

 

 

 

specific

 

 

 

 

 

 

 

SetSlotBlueLed

 

0x13

 

Vendor

 

 

 

 

 

specific

 

 

 

 

 

 

 

SetSlotReset

 

0x15

 

Vendor

 

 

 

 

 

specific

 

 

Table C.2: PMC Controller Support