Znyx Networks bh5700 manual System Hangs During Boot, Booting the Duplicate Flash Image

Models: bh5700

1 359
Download 359 pages 3.51 Kb
Page 142
Image 142

System Hangs During Boot

After attaching the system console cable, if the system hangs during boot, try booting with the –ioption as described in the previous section. It is possible that important Linux system files became corrupted and incorrectly saved in the flash overlay. Use zmnt as described in the previous section to fix or remove the problem files from the overlay. If the system will not boot with the –ioption, refer to Booting the Duplicate Flash Image section in this chapter.

Booting the Duplicate Flash Image

Another recovery method, if Linux fails to boot, is to temporarily boot the factory-installed duplicate image located in the second flash device.

Connect through the console port.

When you see the number counter appear after the “zmonitor …” banner, press any key on the console keyboard to enter the zmon application.

At the monitor prompt, type:

boot:2

You should see the counter again, but the system should boot into the secondary kernel. If you have difficulties booting, contact Hewlett-Packard Technical Support.

At this point, follow the Upgrading the OpenArchitect Image section to put a new RAM disk image in the application flash 1.

IMPORTANT: Be sure not to program flash 2, since this is your only current bootable image.

The command to program flash 1 should be similar to the following command. The image name may be slightly different depending on the model of switch and version of the image:

zflash –d 1 rdr6000.zImage.initrd

Upgrading the OpenArchitect Image

1.Refer to the HP bh5700 14-Slot Blade Server Installation Guide, Chapter 6, 14-Slot Shelf Startup, Validating and Updating Your Firmware for instructions on how to gain access to firmware updates for the HP bh5700 14-Slot Blade Server.

2.Use telnet, or preferably, attach a console cable to the switch, and login to the switch.

IMPORTANT: If you are connecting via telnet, be aware that the upgrade process will reset the switch to the default IP address of 10.0.0.42, so you will have to be able to reach 10.0.0.42.

3.Using the procedures referenced in Step 1, above, download the available OpenArchitect image upgrade to a local system.

4.Check for free space with the df command. The OpenArchitect image is very close to

Ethernet Switch Blade User's Guide

release 3.2.2j

page 142

Page 142
Image 142
Znyx Networks bh5700 manual System Hangs During Boot, Booting the Duplicate Flash Image, Upgrading the OpenArchitect Image