Znyx Networks bh5700 manual FRU State HotSwap Healthy Solution LED Status

Models: bh5700

1 359
Download 359 pages 3.51 Kb
Page 151
Image 151

FRU State

HotSwap

Healthy

Solution

 

LED Status

LED Status

 

 

 

 

 

M0

OFF

OFF

No power. Board not inserted correctly.

 

 

 

 

 

 

1. Remove and re-insert board.

 

 

 

2. If board does not power-up after re-insertion,

 

 

 

try a different slot. If board continues to fail

 

 

 

in the new slot and the problem does not

 

 

 

affect other boards running in the chassis,

 

 

 

return the Ethernet Switch Blade board for

 

 

 

repair.

 

 

 

 

M1

ON

ON

No Communication with the Shelf Manager. Make

 

 

 

 

 

 

sure the hot swap ejector handle is securely closed.

 

 

 

The Hot Swap LED may remain lit or blinking if

 

 

 

awaiting permission to activate from the ShMM

 

 

 

If the Hot Swap handle is closed, retrieve the Mstate

 

 

 

information from the ShMM. Use the tips in the

 

 

 

Accessing the ShMM section below to determine if

 

 

 

other FRUs are also encountering difficulty (could

 

 

 

indicate a chassis-wide failure of the IPMB bus)

 

 

 

 

M2

LONG

OFF

If the switch has reported critical sensor data for

 

BLINK

 

temperature or voltage, the ShMM can prevent the

 

 

 

switch from booting. To determine if the critical

 

 

 

sensor events persist, it may be necessary to alter the

 

 

 

rules enforced by the ShMM to allow the switch to

 

 

 

boot (receive back-end power). See Accessing the

 

 

 

ShMM section, below, for more information

 

 

 

 

M3

OFF

OFF

Check the Shelf Managers to see if the voltage and

 

 

 

 

 

 

temperature sensors are within threshold (see the

 

 

 

Accessing the ShMM section below for how to

 

 

 

retrieve these values or detect critical thresholds

 

 

 

exceeded events), this indicates an internal hardware

 

 

 

fault and inoperable IPMC. Replace the switch.

 

 

 

Follow the other troubleshooting tips in the

 

 

 

Accessing the ShMM section below to determine if

 

 

 

exceeded thresholds are specific to the switch, or

 

 

 

might indicate a chassis-level problem (if other FRUs

 

 

 

are also reporting similar events).

 

 

 

 

M4

OFF

ON

Switch Operational State. Try connecting into the

 

 

 

Ethernet Switch Blade User's Guide

release 3.2.2j

page 151

Page 151
Image 151
Znyx Networks bh5700 manual FRU State HotSwap Healthy Solution LED Status